Specifications

subject to change.

Downdraft Vent

FH36DD50M S

36" In-Cabinet

36" Downdraft Vent - (FH36DD50MS)

Frigidaire Baseline

Downdraft Vent Specifications

•

Voltage Rating – 120V / 60 Hz / 15 Amps

•

Connected Load (kW Rating) @ 120 Volts = 0.41 kW (For use on

adequately wired 120V, dedicated circuit having 2-wire service with a

separate ground wire. Appliance must be grounded for safe operation.)

•

Amps @ 120 Volts = 3.4 Amps

•

Do not use same circuit as cooktop.

•

Always consult local and national electric codes. Check local building

codes for installation requirements, as they may vary per locale.

•

Locate grounded electrical outlet for 28"- long power cord within

reachable distance. When installing vent in 36"- wide cabinet, outlet

cannot be located on back wall of cabinet, but can be wall-mounted

with access hole in cabinet.

•

Downdraft Vent designed for installation with cooktop in island,

peninsula or conventional installation. (Cutout template provided,

packed with vent.)

•

To ensure proper installation with cooktop, refer to model-specific

cooktop installation guide on web for dimensions, countertop

cutout dimensions and cabinet requirements; oversized cabinets

recommended for ease of installation. Due to varying cooktop depths,

tight fit is possible between cooktop and vent, depending on overall

depth of countertop.

•

Pre-formed countertops with raised lip and /or backsplash may not

allow enough flat area for proper installation. Minimum 2-5/16" of flat

countertop required behind cooktop and 2-1/16" necessary between

back edge of cooktop and inside of cabinet back.

•

To ensure adequate clearance for air vent when raised /lowered, 1/8"

gap needed between back edge of cooktop and front of downdraft

top trim.

•

Vent exhaust air outside only.

•

Exhaust Duct Required – Galvanized or aluminum duct in 6" round

or 3-1/4" x 10" rectangular, or combination of both. PVC should

be used if installing under concrete slab.

•

Three blower discharge direction options available; rotate blower

motor for left, right or down discharge.

•

Consider ductwork location before cutting hole in cabinet. Blower

motor mounted on slide plate, enabling 3-1/2" left or right adjustment

to avoid duct interference with joists or other obstructions.

•

For maximum efficiency, use shortest and straightest duct run

possible. System operates most efficiently with up to 60 equivalent

feet of duct; Downdraft Vent operates properly with ductwork

up to 100 equivalent feet. (Refer to Calculating Duct Length Table

in Product Installation Guide.)

•

Do not use flexible duct. Round duct instead of rectangular duct

recommended, especially when elbows are required.

•

Thermal breaks such as short section of nonmetallic duct, should

be used in areas of extreme cold. Cold weather installations should

have additional backdraft damper installed.

•

High level of airflow may affect gas flame on some gas cooktop

models.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.