Glass Canopy Island Hood

FHPC3660L S

36" Stainless Steel

USA

•

10200 David Taylor Drive

•

Charlotte, NC 28262

•

1-800-FRIGIDAIRE

•

frigidaire.com

CANADA

•

5855 Terry Fox Way

•

Mississauga, ON L5V 3E4

•

1-800-265-8352

•

frigidaire.ca

FHPC3660L 02/12

© 2012 Electrolux Home Products, Inc.

Specifications

subject to change.

Glass Canopy Island Hood Specifications

•

Product Shipping Weight (approx.) – 88 Lbs.

•

Island / Peninsula Ceiling-Mount Installation

•

Ventilation system is preset to exhaust air outside. If outside

ducting is not possible, optional Duct-Free Recirculation Kit

(PN # FHPRKT60LS) is available to convert ventilation to allow air

to recirculate inside. (Refer to Ducted Option Specifications for

outside ventilation.)

•

Sones Rating – 6.5

•

Voltage Rating – 120V / 60 Hz / 15 Amps

•

Connected Load (kW Rating) @ 120 Volts = 0.52 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire

service with a separate ground wire. Appliance must be grounded

for safe operation.)

•

Amps @ 120 Volts = 4 Amps

•

Always consult local and national electric codes. Check local building

codes for installation requirements, as they may vary per locale.

•

Minimum installation height allowed from bottom of hood to standard

36"-high electric or gas cooking surface is 24" - 36". (NOT more than

32" recommended.) For detailed instructions regarding install heights

in 8', 9' and 10' ceiling applications, refer to installation guide on web.

•

To prepare mounting surface, adequate structure and support must

be provided, capable of supporting 150 lbs.

Ducted Option Specifications

•

For outside ventilation.

•

Exhaust Duct Required – 6" round

•

For most efficient airflow exhaust, use a straight run or as few

elbows as possible.

•

Use metallic flex ducting only to connect rigid duct directly to

transitions (if allowed by code).

•

Thermal breaks such as short section of nonmetallic duct, should

be used in areas of extreme cold.

•

Cold weather installations should have additional backdraft damper

installed.

•

Refer to installation instructions on web for detailed exhaust duct

preparation and converting vent blower system for recirculating inside.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Pre-Installation Calculations

•

Select hood preference height (P) that is comfortable for user

(24" - 36" minimum allowed, NOT more than 32" recommended).

•

Calculate hood height (H) for installation (H = K-C-P).

•

Confirm that (H) is within minimum to maximum range for hood. If

not, adjust installation.

•

Calculate chimney structure height (S). Use formulas, check

dimensions of hood. Save calculation for use later in installation.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Optional Accessories

•

Duct-Free Recirculation Kit – (PN # FHPRKT60LS).

•

10' Flue Extension Kit – (PN # FHP10X60LS).