40" dual fuel range installation instructions – FRIGIDAIRE FPDF4085KF User Manual
Page 5
 
5
40" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
(Models with Electric Ovens and Gas Cooktop)
Direct Electrical Connection to the Circuit 
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit 
breaker,	fuse	box	or	junction	box,	use	flexible,	armored	
or nonmetallic sheathed copper cable (with grounding 
wire). Supply a U.L. listed strain-relief at each end of 
the cable. At the appliance end, the cable goes through 
the Direct Connection Hole (see Figure 5) on the Cord 
Mounting Plate. Wire sizes (copper wire only) and 
connections must conform to the rating of the appliance.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire 
(see Figure 5):
1. Be sure that no power is supplied on the cable from 
residence.
2. Remove the grounding strap from the terminal block
and from the appliance frame.
3.	 In	the	circuit	breaker,	fuse	box	or	junction	box:
 a) Connect the green (or bare copper) wire, the white 
appliance cable wire, and the neutral (white) wire 
together.
 b) Connect the 2 black wires together.
 c) Connect the 2 red wires together.
Figure 5
3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)
Cable from Residence
Junction
Box
White Wire
U.L.-listed Conduit
Connector (or CSA
listed)
Cable from
Appliance
Green
(or Bare Copper)
Wire
Red
Wires
Neutral
(white) Wire
Black
Wires
NOTE: Be sure to remove the
supplied grounding strap.
Where local codes DO NOT permit connecting the 
appliance-grounding conductor to the neutral 
(white) wire, or if connecting to 4-wire electrical 
system (see Figure 6):
1. Be sure that no power is supplied on the cable from 
residence.
2. Remove the grounding strap from the terminal block
and from the appliance frame.
3. In the circuit breaker, fuse box or junction box:
a) Connect the white appliance cable wire to the
neutral (white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding 
wire to the grounding wire of the circuit breaker, 
fuse	box	or	junction	box.
NOTE: Be sure to remove the
supplied grounding strap.
U.L.-listed Conduit
Connector (or CSA
listed)
Figure 6 – 4-Wire Electrical System
(Example: Junction Box)
Cable from Residence
Black
Wires
Junction
Box
White Wire
Cable from
Appliance
Green (or Bare
Copper) Wire
Red
Wires
White Wire
Green (or Bare
Copper) Wire