12

STARTING/STOPPING INSTRUCTIONS

Red EZ-Fire™

Lever

On/Off Stop Control

Throttle Control

Idle

Fast

STARTING INSTRUCTIONS

Fig. 10

STOPPING INSTRUCTIONS

1. Move the throttle control to the idle position

(

). Allow the engine to cool down by idling

(Fig. 10).

2. Put the On/Off Stop Control in the OFF (O)

position (Fig. 10).

2. The On/Off Stop Control is in the ON (I) position at all

times (Fig. 10).

3. Fully press and release the primer bulb 10 times,

slowly. Some amount of fuel should be visible in the
primer bulb
and fuel lines (Fig. 10). If you can’t see fuel
in the bulb, press and release the bulb as many times

as it takes before you can see fuel in it.

4. Place the unit in the starting position (Fig. 11) as a

blower, Fig. 12 as a vacuum). Move the throttle
control to the idle position
(

) (Fig. 9). This is

especially important during cold starting.

5. Push the red EZ-Fire™ Lever towards the primer

bulb until it clicks and locks into place (Fig. 10).

NOTE: The unit uses the Incredi-Pull™ starting system

with MAX FIRE IGNITION™, which significantly
reduces the effort required to start the engine. You
must pull the starter rope out far enough to hear
the engine attempt to start. There is no need to pull
the rope briskly-- there is no harsh resistance when
pulling. Be aware that this starting method is vastly
different from (and much easier than) what you may
be used to.

6. Pull the starter rope out with a controlled and steady

motion until the engine attempts to start. Repeat until

the engine starts.

7. When the engine starts, move the throttle control to the

fast position (

) and let the engine warm up for 15 to

30 seconds. The red EZ-Fire™ Lever will click off

automatically when you move the throttle control to

the fast position.

IF...

The engine does not start, go back to step 3.

IF...

The engine stops while moving the throttle, go back
to step 5.

IF...

The engine stops before you move the throttle, move
the throttle to the fast position and pull the starter
until the blower starts.

NOTE: If you are having trouble starting the unit or are

operating in extreme temperatures (below 40º F, above

90º F), refer to the Troubleshooting section.

Vacuum
Starting

Position

Starter

Rope

Starter

Rope

Blower

Starting

Position

Fig. 11

Fig. 12

Operate this unit only in a
well-ventilated outdoor area.

Carbon monoxide exhaust fumes can be lethal in a
confined area.

WARNING:

Avoid accidental starting.
Make sure you are in the

starting position when pulling the starter rope (Fig. 11
and 12). To avoid serious injury, the operator and unit
must be in a stable position while starting.
Do not set unit on any surface except a clean, hard
area while starting. Debris such as gravel, sand, dust
and grass could be picked up by the air intake and
thrown out by the discharge opening. This could
damage the unit, property, or cause serious injury to
bystanders or the operator.

WARNING:

To avoid serious

personal injury,

always remove the vacuum bag prior to

refueling the unit. The bag may become a

fire hazard when saturated with fuel.

WARNING:

Primer

Bulb

1. Mix gas with oil. Fill fuel tank with fuel/oil mixture.

See Oil and Fuel Mixing Instructions.

Fig. 9

Blower/Vac

Equipped With

Incredi-Pull

Starting