8 specifications – Crown 1201 User Manual

Page 20

Advertising
background image

Micro-Tech Series Power Amplifiers

page 20

Operation Manual

Performance

MT-600

MT-1200

MT-2400

Voltage Gain (at maximum level setting, ± 0.5 dB)
26dB sensitivitiy
0.775V sensitivity
1.4V sensitivity

26 dB

35.0 dB
30.0 dB

26 dB

36.0 dB
31.0 dB

26 dB

38.0 dB
33.0 dB

Required AC Mains

50/60 Hz, 100 - 240 VAC (±10%)

50/60 Hz, 100 - 240 VAC (±10%)

50/60 Hz, 100 - 240 VAC (±10%)

Power Draw at Idle

90 watts

90 watts

90 watts

Cooling

Flow-through ventilation from front to side

panels. Internal heat sinks with forced air

cooling.

Flow-through ventilation from front to side

panels. Internal heat sinks with forced air

cooling.

Flow-through ventilation from front to side

panels. Internal heat sinks with forced air

cooling.

Dimensions: Width, Height, Depth

EIA Standard 19 in. x 3.5 in. (8.9cm)

x 16 in. (40.6 cm)

EIA Standard 19 in. x 3.5 in. (8.9cm)

x 16 in. (40.6 cm)

EIA Standard 19 in. x 3.5 in. (8.9cm)

x 16 in. (40.6 cm)

Weight (120VAC, 60-Hz units)
Net Weight
Shippping Weight

36 lb 4 oz (16.5 kg)
41 lb 2 oz (18.7 kg)

41 lb 1 oz (18.6 kg)

45 lb 3 oz (20.5 kg)

46 lb 14 oz (21.3 kg)
55 lb 12 oz (25.3 kg)

Weight (International units)
Net Weight
Shipping Weight

38 lb 7 oz (17.9 kg)
44 lb 2 oz (20.0 kg)

41 lb 0 oz (18.6 kg)
45 lb 4 oz (20.5 kg)

47 lb 9 oz (21.6 kg)
56 lb 6 oz (25.6 kg)

8 Specifications

Advertising