Extension cords, Symbology – Chicago Electric 80W Plastic Welding Kit with Iron 67102 User Manual

Page 6

Advertising
background image

Page 6

SKU 67102

For technical questions, please call 1-800-444-3353.

Grounding prong in plug is connected

2.

through green wire inside cord to

grounding system in tool. Green wire

in cord must be only wire connected

to tool’s grounding system and must

never be attached to “live” terminal.

(see 3-prong plug and outlet.)
Tool must be plugged into appropriate

3.

outlet, properly installed and

grounded in accordance with codes

and ordinances. Plug and outlet

should look like preceding illustration.

(see 3-prong plug and outlet.)

extension cords

Grounded

1.

tools require a three wire

extension cord. Double Insulated

tools can use either a two or three

wire extension cord.
As distance from supply outlet

2.

increases, use a heavier gauge

extension cord. Using extension

cords with inadequately sized wire

causes a drop in voltage, resulting

in loss of power and possible tool

damage. The smaller the gauge

number of wire, the greater capacity

of cord. For example, a 14 gauge

cord can carry a higher current than a

16 gauge cord.

(see table a.)

When using more than one extension

3.

cord to make up the total length,

make sure each cord contains at

least the minimum wire size required.

(see table a.)
If using extension cord for more than

4.

one tool, add nameplate

amperes

and use sum to determine required

minimum cord size.

(see table a.)

If using extension cord outdoors,

5.

make sure it is marked with “W-

A” (“W” in Canada) to indicate it is

acceptable for outdoor use.
Make sure extension cord is properly

6.

wired and in good electrical condition.

Always replace damaged extension

cord or have it repaired by a qualified

electrician before using it.
Protect extension cords from sharp

7.

objects, high heat, and wet areas.

recoMMended MiniMuM wire

gauge For eXtension cords*

(120/240 Volt)

naMeplate

aMperes

(at full load)

eXtension cord

length

25’

50’

75’

100’

150’

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

taBle a

* Based on limiting the line

voltage drop to five volts at

150% of the rated amperes.

symbology

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

a

Amperes

n0 xxxx/min.

No Load Revolutions per Minute

(RPM)