Cecilware GB-IT User Manual

Page 9

Advertising
background image

9

GREEN – DISPENSE BUTTON

RED – LED BLINKING LIGHTS

To decrease or increase parameters

To access SERVICE MODE – Press simultaneously

Center of CECILWARE LOGO and Center of FAST FLOW LOGO

To access PROGRAM MODE – Press simultaneously

RINSE and STOP

PLEASE SELECT DRINK…..

LCD WINDOW

25. Default Parameters – This screen gives the user the ability to reset all system parameters except the Grand Total, Dispense Total, and

Cups Dispensed. Simultaneously depressing the and keys will force all system parameters to revert to designated individual default

settings.

*Important Note* The default status for all Hoppers is OFF. Thus before any Hopper will dispense the Hopper Status must be

manually set to ON.


PROGRAMMING INSTRUCTIONS – ILL. C









The a functional description of Version 1.07 of the dispensing controller is as follows:

MODES OF OPERATION

1. Initializing Mode – This mode is only active during the first few seconds after a “power-on” or system reset. The main function of this

mode is to configure the system using the previously saved operating parameters.

2. Normal Mode – This mode becomes active immediately after Initializing Mode has completed its tasks. The main functions of this mode

are to monitor and report system status and control dispensing.

3. Rinse Mode – This mode becomes active when the Rinse key is depressed while in Normal Mode. The main function of this mode is to

allow the operator to initiate an individual Rinse for any enabled Hopper.

4. Program Mode – This mode becomes active when the Rinse and the Stop keys are simultaneously depressed for more than 1.5 seconds

while in Normal Mode. The main function of this mode is to provide limited access to frequently used system parameters.

5. Service Mode – This mode becomes active when the hidden keys under the “Cecilware Logo” and the “Fast Flow Logo” are

simultaneously depressed for more than 1.5 seconds while in Normal Mode. The main function of this mode is to allow access to all

system parameters that can be modified.


INITIALIZING MODE

The following screen signifies this presence of this mode:

It should be noted that this is the only time the System Software Version Number (V #.##) is displayed.
All other functions of this mode are completely transparent to the operator.

NORMAL MODE

The following is a list of functions performed by this mode:
1. Dispensing Control – This mode is responsible for implementing and supervising the dispensing process.
2. Water Level Control – This mode is responsible for maintaining the proper level of water in the reservoir tank.
3. Water Temperature Control – This mode is responsible for maintaining the required water temperature in the reservoir tank.
4. Sanitary (Rinse) Functions – This mode is responsible for annunciating and enforcing rinse warnings and lockouts.
5. Safety Functions – This mode is responsible for monitoring all sensors, motors, solenoids, and heaters for proper operation.

RINSE MODE

An individual Rinse is initiated by simultaneously pressing the Rinse key and a Dispense key corresponding to the hopper to be rinsed.

CECILWARE

DISPENSER V #.##

Advertising