Warning, Safety considerations, Hr v – Carrier HRVCCLVU User Manual

Page 2

Advertising
background image

2

OFF

HIGH

LOW

ARRET

HAUTE

BASSE

% D HUMIDITE RELATIVE HUMIDITY

20

25

30

40

50

60

70

80

OFF

ARRET

LOW

BASSE

INTERMITTENT

AIR EXCHANGE

ECHANGE D´AIR

´

ON

MARCHE

% HUM. RELATIVE HUM.

55%
45%
35%
30%

EXT. TEMP. EXT.

% D´HUMIDITE RELATIVE HUMIDITY

´

% HUM. RELATIVE HUM.

55%
45%
35%
30%

EXT. TEMP. EXT.

MODE

AIR EXCHANGE

ECHANGE D´AIR

´

20

25

30

40

50

60

70

80

10°C/50°F

0°C/32°F

–10°C/14°F

–20°C/–4°F

´

´

10°C/50°F

0°C/32°F

–10°C/14°F

–20°C/–4°F

OneTouch

TM

Control

Basic Control

Standard Control

Automatic Control

(Not compatible with the following series:

HRVCCSHB and HRVCCSVB)

INTERMITTENT

MAX
MIN

A10003

Fig. 2 -- Controls

SAFETY CONSIDERATIONS

Recognize safety information. This is the safety--alert symbol
When you see this symbol on the unit and in instructions or

manuals, be alert to the potential for personal injury. Understand

these signal words; DANGER, WARNING, and CAUTION. These
words are used with the safety--alert symbol. DANGER identifies

the most serious hazards which will result in severe personal injury
or death. WARNING signifies hazards which could result in

personal injury or death. CAUTION is used to identify unsafe

practices which would result in minor personal injury or product
and property damage. NOTE is used to highlight suggestions

which will result in enhanced installation, reliability, or operation.

OPERATING YOUR HEAT RECOVERY

VENTILATOR (HRV) WITH

ONE TOUCHT CONTROL:

Press “PUSH” until the desired ventilation operation is selected.

There are three selections:
High, Low, Intermittent. The power indicator light indicates which

mode has been selected.
High: This mode is recommended for the removal of excess

pollutants and humidity. The ventilator will operate at its

maximum speed continuously. The power indicator light will be lit
red when this mode is selected.
Low: This mode is recommended for normal daily operation. The
ventilator will operate at its minimum speed continuously. The

power indicator light will be lit yellow when this mode is selected.
Intermittent: This mode is recommended when the inside air is too

dry in the heating season or too humid in the cooling season. The

ventilator will operate at its minimum speed for 20 minutes per
hour and be off for 40 minutes per hour. The power indicator light

will be lit green when this mode is selected.
Off: To turn the ventilator off, press “Push” until the power

indicator light is turned off.

OPERATING YOUR HEAT RECOVERY

VENTILATOR (HRV) WITH BASIC,

STANDARD AND AUTOMATIC CONTROL

Your HRV is designed to operate as an integral part of your total

heating and cooling system. With the exception of high capacity
models, which are available with standard controls only, all HRVs

offer 4 control options (See Fig. 2).

S

Basic Controls:Allow the user to manually set the unit to low--
or high-- fan speed as required to maximize comfort. Controls

may be unit mounted.

S

Standard Controls: Offer automatic dehumidistat control and the
option to select low speed or intermittent fan during heating
season.

S

Automatic Controls: In addition to the operational features
found with standard controls, automatic controls feature a
recirculation mode. Not for use with forced--air HVAC systems.

Fan Speed Control — Enables user to modulate fan speed from

low to high.
Dehumidistat Control — Allows the user to select the relative
humidity level at which the unit would change fan speed to avoid

condensation problems while heating during the winter months.
(See Table 1).
Continuous Mode — If the relative humidity inside the building

is lower than selected, air exchange would occur with the outside at
low speed. If the relative humidity level inside the building is

higher than selected, air exchange would occur outside at high
speed. This ensures continuous air exchange for constant air

quality.
Intermittent Mode — If the relative humidity inside the building
is lower than selected, no air exchange would occur, and the

system would turn off. If the relative humidity inside the building
is higher than selected, air exchange would occur with outside at

high speed. This ensures minimum air exchange level when the
building is unoccupied to minimize operating cost.
Recirculation Mode — If the relative humidity inside the building

is lower than selected, indoor air would be circulated and filtered at
high speed. If the relative humidity inside the house is higher an

selected, air exchange would occur with outside at high speed. This
ensures continuous movement and filtration of air for maximum

comfort.

ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury

or death.
Before servicing system, always turn off main power to

system. Turn off accessory heater power if applicable. There

may be more than 1 disconnect switch.

!

WARNING