40542-A REAR REGISTER KIT (Optional Accessory)

INSTALLATION INSTRUCTIONS FOR GRAVITY VENTED WALL FURNACES

STEP 1.

Cut hole within stud space behind heater in the back wall 8-1/4” high by 12-5/8” wide. The lower
edge of the hole to be 45-3/4” above the floor plate or 47” from the floor (with standard 2”x4”
floor base) as shown in Figure 13.

STEP 2.

Install plaster ground frame for rear register in hole and nail frame to stud as shown in Figure 14.

STEP 3.

REAR REGISTER INSTALLATION: Cut and remove embossed plates in inner and outer casing.
Follow instructions for installation of regular furnace.

STEP 4.

After furnace is installed, attach rear register grille as shown in Figures 16 & 17 by insertion over

plaster ground and attach with sheet metal screws, provided.

STEP 5.

Damper as shown in Figure 17 can be adjusted from full open for maximum heat to fully closed.

Page 18

14-3/8”

12-5/8”

8-1/4”

PLASTER

PLASTER

STUD

PLASTER

STUD

PLATE

45-3/4”

ROUGH-IN DIMENSIONS FOR REAR REGISTER

FIGURE 13

OPENING 7/8”
FROM EACH
STUD

HOLE FOR
BACK
REGISTER

PLASTER

PLASTER

PLASTER

STUD

STUD

PLATE

NAIL TO
STUD

PLACING FRAME FOR REAR REGISTER

FIGURE 14

40542-A REAR REGISTER KIT

(Used on Single Wall models only)

40542 REAR REGISTER KIT

(W25/35 Series only)

Ref.

Part

Part Description

No.

No.

Damper

22

40375

Damper Spring

23

40377

Frame Assembly

24

40365

Register Chain

25

40379

Bell, Pull

26

85003

Register Assembly

27

40355

Installation Instructions

- -

84504

Form #84504
REV. 07/98

Advertising
This manual is related to the following products: