Inspecting burner, Notice, Warning – Desa Tech B User Manual

Page 21

Advertising
background image

21

101808

1/2 GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

If pilot flame pattern is incorrect, as shown in Figure 19.

• turn heater off (see To Turn Off Gas to Appliance, page 19).
• see Troubleshooting, pages 22 through 25.

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect
burner flame pattern. The incorrect burner flame pattern shows yellow tipping of
the flame. It also shows the flame higher than 1/2 the glass panel height.

NOTICE

Do not mistake orange flames with yellow tipping. Dirt or other fine
particles enter the heater and burn causing brief patches of orange
flame.

Figure 20 - Correct Burner Flame Pattern

Figure 21 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 21

• turn heater off (see To Turn Off Gas to Appliance, page 19)
• see Troubleshooting, pages 22 through 25

INSPECTING

BURNER

Continued

WARNING ICON

G 001

WARNING

If yellow tipping occurs, your heater could produce increased
levels of carbon monoxide. If burner flame pattern shows yellow
tipping, follow instructions at bottom of this page.

CORRECT FLAME PATTERN

AT HIGH POSITION

1/2 GLASS HEIGHT

Yellow
Tipping

Advertising