Chief Manufacturing Automated Flat Panel Ceiling Lift CM2C40 User Manual

Page 18

Advertising
background image

CM2C40

Installation Instructions

18

IR-SE15 Programming

IR-SE15 Control Features:

Carrier Frequency:38KHz

Protocol:NEC - Full Repeat

System Code(s):6E (Default) - Multiple Codes
Selected via Key-Press (see below)

To Change System Code:

1.

Press and Release Key 3 + 7 (Enter Setup Mode)

2.

Press and Release Key 8

3.

Press and Release Key 10

4.

Press and Release Key 12 - LED Blinks Twice <Quick>

5.

Select System Code - See Table Below

6.

Press and Release Key 2 - LED Blinks 4 times <Quick>
(Exit Setup Mode)

Figure 30

Table 1-2: IR-SE15 Control Codes

Key Number

Key Name

Hex Code

1

HOME

02

2

SAVE

1A

3

UP

07

4

LEFT

09

5

STOP

0A

6

RIGHT

0B

7

DOWN

0D

8

PRESET 1

12

10

PRESET 2

13

12

PRESET 3

14

Table 1-3:

System

Code

Press +

Release

6E (Default)

8

E1

8,8,8,8

E2

10

E3

10,8

E4

10,8,8

E5

10,8,8,8

E6

10,8,8,8,8

E7

12

1

2

3

7

5

6

8

10

12

4