5

Operating intervals:

• The manufacturer does not recommending using the appliance continuously for a period of time exceeding

30 minutes.

• It is a normal occurrence that during long grinding periods the grinding chamber will heat up. In order to

achieve best grinding results, it is recommended to grind coffee in short intervals of a few minutes each.

Adjusting coffee grind

• The grinding blades’ distance was factory pre-adjusted to satisfy different common coffee grinds from super

fine to coarse) corresponding gap distance from 0.05mm to 0.5mm.

• Turning the grinding dial incrementally counterclockwise will make the grind finer and turning it clockwise will

make the grind coarser.

• Grind a small amount of coffee and test its coarseness with your espresso machine.
• As coffee beans’ qualities and characteristics are changing from time to time it is recommended repeating

this adjustment once in a while.

Adjusting coffee dosing

• The doser is equipped with a portion displacement controlling knob.
• In order to increase the dosed amount the knob should be turned counterclockwise and vice versa (Fig 5.).
• Test the portioned amounts by inserting a porta filter handle (not supplied) all the way into the fork shaped

support and dose one or two portions.

• In order to achieve repeatable and consistent portioned amounts:

o Make sure that the feeding star shaped mechanism is always over filled with coffee.
o Always retract the dosing lever all the way to the end of its stroke.

Pressing

• Place the porta filter holder against the underside of the pressing device and push it upwards.

6) Safety Devices

A) Thermal Overload Protection

In order to eliminate the risk of fire the motor is equipped with an over-heat protection device which will cut-off
the motor’s power supply should it reach a high temperature.

• In the event that the thermal protection is tripped as a result of malfunction (e.g.: jammed blades, worn out

bearings, foreign object in grinding chamber, etc.) the appliance main switch should be turned off
immediately and the main power plug must be disconnected. For further handling of the device contact your
local service provider, and allow the appliance to cool down before any further maintenance.

• In the event that the thermal protection is tripped as a result of a long continuous operation (read section 5,

for operating intervals) allow the appliance to cool down and reset the thermal cut off protection by
unplugging the main cable from the socket. On the first operation after resetting a tripped over-heat

Figure 5.1

Safety Screw

Figure 5.

Advertising