Installation instructions, Natural gas l.p.g – Creda X152 User Manual

Page 19

Advertising
background image

Installation Instructions

19

Technical Data

Dimension

General

BURNER

HEAT INPUT

INJECTOR

HEAT INPUT

INJECTOR

Natural Gas

L.P.G

HOTPLATE

Front left

HOTPLATE

Rear right

HOTPLATE

Front right

HOTPLATE

Rear left

GRILL

OVEN

3.0 kW

2.0 kW

1.0 kW

3.8 kW

2.5 kW

128

102

72

150

115

2.8 kW (205g/h)

1.8 kW (130g/h)

1.0 kW (75g/h)

3.4 kW (245g/h)

2.5 kW (180g/h)

82

65

50

2.0 kW

102

1.8 kW (130g/h)

65

95

75

Height 900mm
Width

500mm

Depth

600mm (excluding door handles)

Gas connection

Rp

1

/

2

(

1

/

2

” BSP female)

Pressure test point

Grill injector

Gas rate adjustment

None

Aeration adjustment

None

Battery

1.5V Alkaline AA

Advertising