5 partition for paper roll, 6 setting dip switch, 6 setting dip switch caution – CITIZEN CT-S4000L User Manual

Page 18: Caution

Advertising
background image

— 15 —

InitialSettings

1

Communication condition DIP switch setting

Memory switch

OFF

setting method

setting

2

Hand shake

XON/XOFF

DTR/DSR

OFF

3

Bit length

7 bits

8 bits

OFF

4

Parity check

With parity

None

OFF

5

Parity selection

Even parity

Odd parity

OFF

6

OFF

7

ON

8

INIT

Reset

Invalid

OFF

3.6 Setting DIP Switch

CAUTION!

When using 112 paper roll, the partition is not used.

DIP switch

Interface board
mounting screws

CAUTION!

■ As for the setting of the serial interface, it gives priority to the setting of the memory

switch rather than the DIP switch as the factory default.

■ Consult with the dealer where the printer was purchased when the change of the DIP

switch setting is necessary.

3.5 Partition for Paper Roll

Selecting baud rate

Switch No.

6

7

2400

OFF

OFF

4800

ON

OFF

9600

OFF

ON

19200

ON

ON

38400, 57600 and 115200 bps can also be selected by a command, etc.

Switch No.

Function

ON

OFF

Baud rate selection

See Table below.

Baud Rate (bps)

At the time of shipment, this partition is not installed.

1.

Confirm that the power switch is OFF.

2.

Open the printer cover.

3.

Insert the partition into the slot and align it
with the scale inside of the printer which
meets the width of the paper roll used. When
using the 80mm or 82.5mm wide paper roll,
set the partition by using the accessory screw.
*58 mm is only for label supporting model.

4.

Change the setting of paper width by reffering
to the section 5.2, "Manual Setting of Memory
Switch".

The DIP switch is present on the serial
interface board.
The function of each switch is as shown
below.

Partition

Partition

Scales