Installation – Desa Tech FIREBOX CGFB32CC User Manual

Page 12

Advertising
background image

www.fmiproducts.com

124970-01A

12

INSTALLATION

Continued

Locate the recessed knockout in one of the

firebrick sidewall liners (see Figure 8 on page

11 and Figure 9). Firmly tap the center of the

knockout with a chisel until it is released.

Carefully chisel the rough edges of the hole

you have made to smooth edges. This hole

will line up with the hole in the outer casing.
Locate the recessed knockout in one of the

firebrick sidewall liners (see Figure 8 on page

11 and Figure 9). Firmly tap the center of the

knockout with a chisel until it is released.

Carefully chisel the rough edges of the hole

to smooth edges. This hole will line up with

the hole in the outer casing.

cAutIoN: do not use exces-

sive force to remove the knock-

out. too much force may damage

the firebrick concrete insert.

Figure 9 - Location of Knockout for Gas

Line

Knockout

Chisel

Firebrick Side Wall

Remove

this Area

Side

View

NotIce: if a log set is installed

in the firebox, disconnect log

set from gas supply and remove

from firebox. Contact a qualified

service person to do this.

There are two (2) blower accessory options for

use in the vent-free fireboxes. Blower acces-

sory models are BK and BK3. Model BK is a

rotary squirrel cage type blower with magnetic

attachment and variable speed control. The

BK3 is a triple fan blower system with an on/

off rocker switch.
The blower must be installed by removing the

lower face panel and placing blower into its

proper mounting position.
Decide which way you intend to gain access

into the bottom rear of the firebox to install

the blower accessory. The lower front panel

can be removed easily by snapping out the

front with a flat blade screwdriver. Use cau-

tion not to scratch any surfaces. Models with

louvered front panels can also be removed by

inserting fingertips between slots and gently

pulling out. DO NOT FORCE. The panels are

actually held in place by means of a retention

dimple embossed on the edge of removable

panels.

warninG: if there is a duplex

electrical outlet installed in the

right side of the bottom of the

fireplace base area (see figure

10), be sure that the electrical

power to the outlet is turned off

before proceeding with blower

installation. failure to do this

may result in serious injury.

Duplex Electrical Outlet

Figure 10 - Accessing Duplex Electrical

Outlet Installed in Bottom Right Side of

Firebox

INstAllING optIoNAl bloWeR

AccessoRIes

NotIce: the firebox identifica-

tion label (including model num-

ber, serial number, clearances,

etc.) is located in the right side

screen pocket area on the front

of the firebox. see figure 19,

page 16.

Note: Appearance of firebox may vary
depending on model.

Advertising