Performance

Frequency Response (at 1 watt) 20 Hz to 20 kHz:
±0.25 dB.

Signal-to-Noise Ratio, A-weighted, below rated
power
(20 Hz to 20 kHz): 105 dB.

Total Harmonic Distortion (THD) at full rated
power, from 20 Hz to 20 kHz
CTs 600 & CTs 1200: < 0.1%.
CTs 2000 & CTs 3000: < 0.35%.

Damping Factor, 10 Hz to 100 Hz: > 3000.

Crosstalk (below rated power, 20 Hz to 1 kHz):
> 80 dB.

Voltage Gain (at maximum level setting)
8/4-ohm operation, 1.4V sensitivity
CTs 600: 35:1 (31 dB).
CTs 1200: 50:1 (34 dB).
CTs 2000: 63.9:1 (36 dB).
CTs 3000: 71.4:1 (37 dB).

26 dB: 20:1 (26 dB).

70V operation, 1.4V sensitivity or
100V operation, 2.0V sensitivity: 50:1 (34 dB).

Common Mode Rejection (CMR) (20 Hz to 1 kHz,
typical): 50 dB.

Maximum Input Level: +20 dBu before input com-
pression, +32 dBu absolute maximum.

Load Impedance (safe with all types of loads):
Stereo, 2 to 16 ohms, 70V and 100V*; Mono, 4 to
16 ohms, 140V and 200V.

Input Impedance (nominal): 10 kilohms balanced,
5 kilohms unbalanced.

*CTs 600 and CTs 1200 with T-170V or TP-170V

AC Line Voltage and Frequency Configurations
Available
(±10%): 120VAC, 60 Hz and 230VAC,
50 Hz.

Power Draw at Idle (120VAC mains):
CTs 600 & CTs 1200: 24W (standby mode).
CTs 2000 & CTs 3000: 35W (standby mode).

DC Output Offset (shorted input): < ±2 millivolts.

Front Panel Controls and Indicators

Power Switch: Push-on / push-off switch.

Indicators: Bridge Mode, Ready, Signal, Clip,
Thermal, Fault, Data, Power.

Back Panel Controls and Connectors

Power Cord Connector: Standard 15 amp IEC inlet.
Voltage is indicated above IEC inlet.

Reset Switch: Resets the circuit breaker that pro-
tects the power supply.

Speaker Connectors: One four-pole touch-proof
terminal strip. Accepts up to 10 AWG terminal
forks.

Input Connectors: Balanced 3-pin terminal block
connectors, one per channel, on the standard PIP2-
BBY module.

Channel Level Control: One 21-position detented
rotary attenuator per channel, ranging from minus
infinity (–70 dB) to 0 dB gain.

Mode Switch: Two-position switch is used to select
the amplifier’s mode of operation: Dual or Bridge-
Mono.

Highpass Filter: One 3-position switch per channel
selects between OFF, 35 Hz and 70 Hz 3rd-order
filters.

“Y” Input Switch: When set to ON, this switch par-
allels the input signals of the two channels, for use
when the input signal is mono. Also can be used to
daisy-chain the signal to another amplifier.

Ventilation Grille: Front-to-rear forced airflow.

Protection

CTs Series amplifiers provide extensive protection
and diagnostic capabilities, including Thermal Level
Control (TLC), fault, low-pass filters, high-pass
filters, AC under/over voltage protection, DC output
servo, circuit breaker, in-rush limiting, and Junction
Temperature Simulation (JTS) in CTs 600/1200.

Construction

Ventilation: Front-to-rear forced airflow. Two
continuously variable speed fans direct the airflow
through the amplifier for cooling.

Dimensions:

EIA Standard 19-inch (48.3-cm)

rack mount width (EIA RS-310-B), 3.5-inch
(8.9-cm) height and 14.25-inch (36.2-cm)
depth behind the mounting surface.

Weight

Net Weight:
CTs 600: 22.8 lbs. (10.3 kg).
CTs 1200: 23.4 lbs. (10.6 kg).
CTs 2000: 27.0 lbs. (12.2 kg).
CTs 3000: 27.7 lbs. (12.6 kg).

Shipping Weight;
CTs 600: 27.7 lbs. (12.6 kg).
CTs 1200: 28.3 lbs. (12.8 kg).
CTs 2000: 32.0 lbs. (14.5 kg).
CTs 3000: 32.7 lbs. (14.8 kg).

System Solutions

PIP™ LITE, PIP USP3,
PIP USP3/CN.

Regulatory Certifications

Other Applications

Note: Specifications apply to units in Dual mode with
8-ohm loads and rated input sensitivity unless other-
wise specified.

C

rown’s CTs Series amplifiers provide exceptional performance, flexibility and value for installed
sound applications. CTs Series amplifiers feature independent selection of high and low impedance

operation for a specific channel, plus power levels and features that were carefully chosen to match
the requirements of fixed install design. Easy integration with HiQnet™ and CobraNet™ allows CTs
amplifiers to deliver a comprehensive lineup of monitoring and control features along with digital audio
transport for an award-winning digital audio solution.

Advertising
This manual is related to the following products: