Country Flame IWZC-02 User Manual

Page 23

Advertising
background image

Version: 6.0

23

INSULATED CHASE CONSTRUCTION

FIGURE 13: INSULATED CHASE

FACING

1. Combustible material must be installed flush with the fireplace. It may not project in front of

or on the fireplace. This means that the steel front façade of the fireplace must not be
overlapped with the combustible facing material. Figure 14 shows the proper installation of
combustible material with reference to the fireplace front façade.

2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and

onto the steel front façade of the Inglenook Fireplace. Figure 15 shows the proper installation
of non-combustible material with reference to overlapping the fireplace front façade.


MANTEL

The mantel must be installed at least 71 inches above the base of the fireplace. Figure 14 shows the
proper location of the mantel with respect to the base of the fireplace.