Specifications – Louisville Tin and Stove VFT102 User Manual

Page 2

Advertising
background image

Form No. CVF 20M 4/06 Printed in U.S.A.

© 2003 Louisville Tin & Stove Company, Incorporated

Piezo Ignitor – requires no matches to light unit.

Textured Steel Cabinet – resists scratching and
cleans easily with a damp cloth.

Porcelain Hearth & Jamb Assembly – resists heat
discoloration, cleans easily with a damp cloth.

Optional Gas Line Inlet Openings – at unit rear and
bottom for easy installation.

Standard Wall Mount Bracket – with each unit

facilitates installation.

Removable Lower Front Panel – provides easy

access for service and cleaning.

Front Safety Guard – prevents direct burner contact

and injury.

Thermostatic Controls – are factory installed

on 10M, 20M & 30M BTU models for further
operating convenience.

Optional Thermostatic Blower – mounts at

unit rear to circulate heated air and prevent
heat stratification (20M & 30M BTU units only).
Shipping weight – 4 lbs. Operates at 50 CFM
on 115V.

100% O.D.S.

Safety Pilot –
assures safe
operation and
guards against
oxygen deple-
tion or gas flow
interruption.

Top Operated Controls –

facilitates “no stoop”
operation.

VFT/BFT Top Control

VFM Top Control

Optional Freestanding Floor

Kit – for 10M (VF10 FSK), 20M
(VF20 FSK), & 30M (VF30
FSK) BTU units only. Allows
away-from-the-wall installation.
Shipping weight – 2 lbs.

O.P. Pilot for

Natural units

O.P. Pilot for

L.P. units

10 Models to Choose From. . . 5,000 to 30,000 BTU

All units must be installed by a qualified gas serviceman.

Note: Units are not field convertible from one gas to another.

Units installed at altitudes greater than 4,500 ft. may experience nuisance pilot outage.
Units installed in bathrooms and bedrooms must be wall mounted.

Consult local codes, regulations, and ordinances for approved use in your area.

SPECIFICATIONS

INFRA-RED VENT FREE HEATERS

BLUE-FLAME VENT FREE HEATERS

Model No./Nat. Gas

VFM63 VFM103 VFM203

VFM303 VFT101 VFT201 VFT301 BFT101 BFT201 BFT301

Model No./L.P. Gas

VFM64

VFM104

VFM204

VFM304

VFT102

VFT202

VFT302

BFT102

BFT202 BFT302

Control

MANUAL THERMOSTAT BULB THERMOSTAT BULB

Height

22

1

2

"

22

1

2

"

22

1

2

"

22

1

2

"

22

1

2

"

22

1

2

"

22

1

2

"

22

1

2

"

22

1

2

"

22

1

2

"

Width

11

1

2

"

14

9

16

"

20

11

16

"

26

13

16

"

14

9

16

"

20

11

16

"

26

13

16

"

14

9

16

"

20

11

16

"

26

13

16

"

Depth

7

"

7

"

7

"

7

"

7

"

7

"

7

"

7

"

7

"

7

"

Input (BTU/hr.)/Nat.

5,500

10,000

20,000

30,000

10,000 20,000 30,000

10,000

20,000 30,000

Input (BTU/hr.)/L.P. 5,000

10,000

20,000

30,000

10,000 20,000 30,000

10,000

20,000 30,000

Gas Supply Line Size

1

2

"

1

2

"

1

2

"

1

2

"

1

2

"

1

2

"

1

2

"

1

2

"

1

2

"

1

2

"

Optional VFB Blower

No

No

Yes

Yes

No Yes

Yes

No

Yes Yes

Optional FSK

No

Yes

Yes

Yes

Yes Yes

Yes

Yes

Yes Yes

Bathroom Installation

Yes

No

No

No

No No

No

No

No No

Bedroom Installation

Yes

Yes

No

No

Yes No

No

Yes

No No

Piezo Ignitor

Yes

Yes

Yes

Yes

Yes Yes

Yes

Yes

Yes Yes

Shipping Weight

16 lbs.

22 lbs.

30 lbs.

35 lbs.

22 lbs. 30 lbs. 35 lbs.

22 lbs.

32 lbs. 35 lbs.

Advertising
This manual is related to the following products: