Specifications – Louisville Tin and Stove VFT102 User Manual
Page 2
Form No. CVF 20M 4/06 Printed in U.S.A.
© 2003 Louisville Tin & Stove Company, Incorporated
■
Piezo Ignitor – requires no matches to light unit.
■
Textured Steel Cabinet – resists scratching and
cleans easily with a damp cloth.
■
Porcelain Hearth & Jamb Assembly – resists heat
discoloration, cleans easily with a damp cloth.
■
Optional Gas Line Inlet Openings – at unit rear and
bottom for easy installation.
■
Standard Wall Mount Bracket – with each unit
facilitates installation.
■
Removable Lower Front Panel – provides easy
access for service and cleaning.
■
Front Safety Guard – prevents direct burner contact
and injury.
■
Thermostatic Controls – are factory installed
on 10M, 20M & 30M BTU models for further
operating convenience.
■
Optional Thermostatic Blower – mounts at
unit rear to circulate heated air and prevent
heat stratification (20M & 30M BTU units only).
Shipping weight – 4 lbs. Operates at 50 CFM
on 115V.
■
100% O.D.S.
Safety Pilot –
assures safe
operation and
guards against
oxygen deple-
tion or gas flow
interruption.
■
Top Operated Controls –
facilitates “no stoop”
operation.
VFT/BFT Top Control
VFM Top Control
■
Optional Freestanding Floor
Kit – for 10M (VF10 FSK), 20M
(VF20 FSK), & 30M (VF30
FSK) BTU units only. Allows
away-from-the-wall installation.
Shipping weight – 2 lbs.
O.P. Pilot for
Natural units
O.P. Pilot for
L.P. units
10 Models to Choose From. . . 5,000 to 30,000 BTU
All units must be installed by a qualified gas serviceman.
Note: Units are not field convertible from one gas to another.
Units installed at altitudes greater than 4,500 ft. may experience nuisance pilot outage.
Units installed in bathrooms and bedrooms must be wall mounted.
Consult local codes, regulations, and ordinances for approved use in your area.
SPECIFICATIONS
INFRA-RED VENT FREE HEATERS
BLUE-FLAME VENT FREE HEATERS
Model No./Nat. Gas
VFM63 VFM103 VFM203
VFM303 VFT101 VFT201 VFT301 BFT101 BFT201 BFT301
Model No./L.P. Gas
VFM64
VFM104
VFM204
VFM304
VFT102
VFT202
VFT302
BFT102
BFT202 BFT302
Control
MANUAL THERMOSTAT BULB THERMOSTAT BULB
Height
22
1
⁄
2
"
22
1
⁄
2
"
22
1
⁄
2
"
22
1
⁄
2
"
22
1
⁄
2
"
22
1
⁄
2
"
22
1
⁄
2
"
22
1
⁄
2
"
22
1
⁄
2
"
22
1
⁄
2
"
Width
11
1
⁄
2
"
14
9
⁄
16
"
20
11
⁄
16
"
26
13
⁄
16
"
14
9
⁄
16
"
20
11
⁄
16
"
26
13
⁄
16
"
14
9
⁄
16
"
20
11
⁄
16
"
26
13
⁄
16
"
Depth
7
"
7
"
7
"
7
"
7
"
7
"
7
"
7
"
7
"
7
"
Input (BTU/hr.)/Nat.
5,500
10,000
20,000
30,000
10,000 20,000 30,000
10,000
20,000 30,000
Input (BTU/hr.)/L.P. 5,000
10,000
20,000
30,000
10,000 20,000 30,000
10,000
20,000 30,000
Gas Supply Line Size
1
⁄
2
"
1
⁄
2
"
1
⁄
2
"
1
⁄
2
"
1
⁄
2
"
1
⁄
2
"
1
⁄
2
"
1
⁄
2
"
1
⁄
2
"
1
⁄
2
"
Optional VFB Blower
No
No
Yes
Yes
No Yes
Yes
No
Yes Yes
Optional FSK
No
Yes
Yes
Yes
Yes Yes
Yes
Yes
Yes Yes
Bathroom Installation
Yes
No
No
No
No No
No
No
No No
Bedroom Installation
Yes
Yes
No
No
Yes No
No
Yes
No No
Piezo Ignitor
Yes
Yes
Yes
Yes
Yes Yes
Yes
Yes
Yes Yes
Shipping Weight
16 lbs.
22 lbs.
30 lbs.
35 lbs.
22 lbs. 30 lbs. 35 lbs.
22 lbs.