Cleveland Range 22CET6.1 User Manual

Page 2

Advertising
background image

(NOT TO SCALE)

SECT.

B

PAGE

4

0507

Litho in U.S.A.

21.63"

549mm

1.44"
37mm

4.00"
102mm

1.44"

37mm

18.74"

467mm

4.32"
110mm

4.25"

108mm

1.69"

43mm

2.25"
57mm

2.38"

60mm

22.00"

559mm

26.75"

679mm

30.75"

781mm

18.13"

461mm

31.19"

792mm

28.13"

715mm

2.00"

51mm

217˚

49.32"

1253mm

D

D

C

C1 C

C2

1.5"

38mm

2.5"

64mm

1.06"

27mm

D

C

RIGHT SIDE VIEW

FRONT VIEW

TOP

VIEW

REAR VIEW

1.5"
38mm

3/4” IPS

DRAIN VENT

CAPPED ACCESS

PORT FOR DRAIN

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L/NSF#4 and CSA (AGA, CGA).

• Each compartment has capacity for: Six, 12˝ x 20˝ x 21⁄2˝ deep Cafeteria Pans.

• Each compartment has capacity for: Twelve, 12˝ x 20˝ x 1˝ deep Cafeteria Pans.

• Each compartment has capacity for: Four, 12˝ x 20˝ x 4˝ deep Cafeteria Pans.

COLD WATER

C-1: Feed water for reservoir, 35 Psi Minimum, 60 Psi Maximum.

C-2: Drain condenser water, 35 Psi Minimum, 60 Psi Maximum.

Two 3/4" NH-F (Garden Thread) connections. Use NSF approved hose.

DRAIN CONNECTION

1 1/4 " NPT-M

Do not connect other units to this drain.

Drain line must be vented. Vented drain connection included.

Do not connect drain to PVC pipe.

OPERATING CLEARANCES

3" Left, 3" Right and 4" Rear.

SERVICE CLEARANCES

12" on control side. Contact factory for variances to clearances.

CONTROLS

SureCook 60-minute electro mechanical timer with load compensating feature.

Three function control switch for Timed Cooking and Continuous Steaming.

APPROVALS

UL and

C

UL listed, classified to NSF#4 and Energy Star

H

D

C

C1 C2

ELECTRICAL

WATTS

VOLTS

PHASE

WIRES

CYCLE

AMPS

SUPPLY CONNECTION

HERTZ

WIRE SIZE (COPPER)*

Standard Wattage

Three Phase - 9 kW Standard

13500

208

3

3

60

37.5

6

11300

220

3

3

60

29.7

8

13500

240

3

3

60

32.5

8

11300

440

3

3

60

14.9

12

13500

480

3

3

60

16.2

10

Optional Low Wattage

Three Phase - 6 kW option

9400

208

3

3

60

26.1

8

5440

220

3

3

60

20.9

10

9400

240

3

3

60

22.6

10

5440

440

3

3

60

10.4

14

9400

480

3

3

60

11.4

14

*

For supply connection use only copper wire suitable for at least 75˚C. (167˚F).

WATTS

VOLTS

PHASE

WIRES

CYCLE

AMPS

SUPPLY CONNECTION

HERTZ

WIRE SIZE (COPPER)*

Standard Wattage

Single Phase - 9 kW Standard

13500

208

1

2

60

64.9

4

11300

220

1

2

60

51.4

6

13500

240

1

2

60

56.3

4

11300

440

1

2

60

25.8

8

13500

480

1

2

60

28.1

8

Optional Low Wattage

Single Phase - 6 kW option

9400

208

1

2

60

45.2

6

5440

220

1

2

60

36.1

8

9400

240

1

2

60

39.2

8

5440

440

1

2

60

18.0

10

9400

480

1

2

60

19.6

10