Cleveland Range GFB-50 User Manual

Cleveland, Gas fired steam boilers, Cook chill systems

Advertising
background image

Cleveland

Project ________________________________

Item __________________________________

Quantity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

1333 East 179 St.,

Cleveland, Ohio, U.S.A. 44110

Tel: 1-216-481-4900

Fax: 1-216-481-3782

Web Site: www.ClevelandRange.com

Email: [email protected]

COOK CHILL SYSTEMS

Cook/Chill Systems

SECT.

XIV

PAGE

53

0907

GAS FIRED STEAM BOILERS

MODELS:

GFB-6

GFB-15

GFB-30

GFB-60

GFB-10

GFB-20

GFB-50

Cleveland Standard Features

■ Complete skid-mounted and piped, gas fired Steam Boiler with

Vertical Return System and Blow Down Separator

■ Available for Pressure Ratings from 15 to 150 psi (specify

required operating pressure)

■ Vertical Tubeless design
■ Fully insulated Boiler with top mounted, down-fired burners
■ High Temperature Insulation assists thermal efficiency of 80%
■ Spinning Cyclonic Flame travels down the entire length of the

Combustion Chamber

■ Top Flame Retainer increases occupancy time of flue gases to

complete combustion process

■ Operating Pressure Control and High Limit Pressure Control

with Manual Reset

■ Water Column with Water Gauge Assembly
■ All necessary valves are included
■ Automatic Water Feed System with probe type Water Level

Controls and single phase Motor for Pump

■ Steam Outlet conveniently located at top of Boiler
■ Control Panel factory mounted and wired, ready for power con-

nection

■ Built and stamped to A.S.M.E. Code
■ Registered with the National Board of Boiler & Pressure Vessel

Inspectors

■ Accepted for use in U.S.D.A. Inspected Facilities

Options & Accessories

❐ Stainless Steel outer Jacket
❐ Automatic Boiler Blow-down Controls
❐ Applicable Controls to meet the various special insurance,

local, state or federal code requirements

❐ Electric heated Steam Boilers
❐ Oil-fired Steam Boilers
❐ Cooling Kit for boiler drain
❐ Aquastat automatic drain cooling kit
❐ Larger models availabe on request

Shall be CLEVELAND Model GFB -____, gas-fired, vertical, tube-

less LARGE STEAM BOILER System, _____H.P. (horse power);

Complete with Power Burners; Skid mounted and piped with

Vertical Condensate Return System and Blow-Down Separator

Package; Factory assembled as a self-contained unit, in accor-

dance to U.L. requirements, and A.S.M.E. Section 1 (one) Code;

Guaranteed production of _______ pounds of Steam per hour at

212˚F.

Short Form Specifications