Operation, Humidity selector, Onetouch control – Carrier ENERGY / HEAT RECOVERY VENTILATOR ERVCCSVB1100 User Manual

Page 5: Latent control, Integrated control, Er v /hr v

Advertising
background image

5

between wall control and ERV/HRV connector following color
code. (See Fig. 5 and 10.) Replace top cover assembly.
NOTE: ERV/HRV wall control and circuit board operate on
12VDC.

YELLOW

Y

R

G B

RED

GREEN

BLACK

A98383

Fig. 10 -- Typical Wall Control

Operation

The Standard and Latent wall controls have 4 basic modes of
operation, OFF, LOW, HIGH, and INTERMITTENT. Be sure that

all modes of operation are fully functional. See Table 1 indicating

standard control operation.

1. With switch off, ERV/HRV is inoperative and the LED is

out.

2. With switch on LOW, ERV/HRV continuously exchanges

air with outside. If control is satisfied, blower will run in

low speed, otherwise, blower will run on high speed. The
LED is illuminated all the time.

3. With switch on INTERMITTENT, the ERV/HRV ex-

changes air with outside on high--speed blower, and unit

shuts down when control is satisfied. The ON LED is illu-
minated all the time, and AIR EXCHANGE LED is illumi-
nated only when unit is running.

Humidity Selector

The humidity selector is a built--in control designed to properly
control the level of humidity in the house during the winter and

summer months. This control helps avoid condensation problems

in upper northern regions where indoor humidity is a problem
during the winter season.
NOTE: This control is not to be confused with a dehumidistat
used during the summer months to control high relative indoor
humidity.
Table 2 recommends humidity levels to avoid condensation.

Table 2 – Recommended Humidity Levels

OUTSIDE

TEMPERATURE

DOUBLE---PANE

WINDOWS

TRIPLE---PANE

WINDOWS

50°F / 10°C

55%

65%

32°F / 0°C

45%

55%

14°F / ---10°C

35%

45%

---4°F / ---20°C

30%

45%

---22°F / ---30°C

25%

35%

OneTouch Control

The OneTouch Control can be used as the primary wall control for
the ERV/HRV. This control will step through the modes of

operation with consecutive presses of the button. The LED

indicates which mode is currently selected, Off, Intermittent, Low,
or High.
NOTE: OneTouch Control does not have a humidity selector.
NOTE: OneTouch Intermittent mode exchanges air on low speed
for 20 minutes per hour.

Latent Control

NOTE: For Latent Controls used with ERV;s, to ensure highest
degree

of

humidity

control

in

cooling

season,

the

INTERMITTENT mode should be used.

Integrated Control

All units are equipped with an integrated control, located under the
unit, in front of the electrical compartment. Use the push button (1)

to control the unit. The LED (2) will then shows on which mode

the unit is in. Integrated Control overrides Wall Control function.
When LED is off, ventilator responds to Wall Control command.

See Fig. 11.

WARNING

Risk of electric shock. Before performing

any maintenance or servicing, always

disconnect the unit from its power source.

AVERTISSEMENT

Danger d’électrocution. Débranchez

toujours l’appareil avant d’entreprendre
des travaux d’entretien ou de réparation.

CAUTION

Unscrew both screws to open the electrical

compartment. To completely remove, detach

from its retention wire inside.

ATTENTION

Dévisser les deux vis pour ouvrir le compartiment

électrique. Pour retirer complètement, le

détacher de son fil de rétention intérieur.

No light OFF or remote controled
Amber light LOW speed
Green ligh HIGH speed
Blinking light See User Manual
Sans lumière Arrêté ou contrôlé
par contrôle mural
Lumière ambre Basse vitesse
Lumière verte Haute vitesse
Clignotant Voir guide d’utilisation

1 2

A07260

Fig. 11 -- Integrated Control

Refer to table below to see how to operate the unit using its
integrated control.

PRESS ON PUSH

BUTTON

LED COLOR

RESULTS

Once

Amber

Unit is on Low

Speed

Twice

Green

Unit is on High

Speed

Three Times

No Light

Unit is OFF

If a problem occurs during the unit operation, its integrated control
LED (2) will blink. The color of the blinking light depends on the

type of error detected. Refer to Troubleshooting for further details.
NOTE: The ERV/HRV may be controlled using the Infinity
system control. The ERV/HRV may be connected using either a
NIM or a 4--Zone Damper Module. See the appropriate instructions
if using the NIM or a 4--Zone Damper Module for connection
instructions.
The Infinity system control will simultaneously control the

ERV/HRV and the indoor blower.
Push Button Timers may be used and are connected to the

ERV/HRV. However, the Infinity system should be set to

continuous fan to ensure that the fresh air is circulated in the home.
In a Zoned System, at least one zone should be set to continuous

fan.