Table 6.1 - resistance checks – Carrier D2-3466-2 User Manual

Page 23

Advertising
background image

Troubleshooting the Drive

6-5

Table 6.1 – Resistance Checks

Input

Diode

No.

Meter

Connection

(+) (-)

Component is OK if

resistance (R) is:

Component is defective if:

1

* SCR1

10 < R < 1 megohm

Continuity (short circuit) or
open when the meter is
connected with reversed
polarity.

2

* SCR2

3

* SCR3

4

* SCR4

5

* SCR5

6

* SCR6

7

SCR1 **

8

SCR2

**

9

SCR3

**

10

SCR4 **

11

SCR5 **

12

SCR6 **

* (+) DC Bus Volts power terminal

** (-) DC Bus Volts power terminal

Table 6.1 - Resistance Checks (Continued)

IGBT

No.

Meter

Connection

(+) (-)

Component is OK if

resistance (R) is:

Component is defective if:

1

* W/T3

10 < R < 1 megohm

Continuity (short circuit) or
open when the meter is
connected with reversed
polarity.

2

* V/T2

3

* U/T1

4

W/T3 **

5

V/T2 **

6

U/T1 **

* (+) DC Bus Volts power terminal
** (-) DC Bus Volts power terminal

Advertising