Power Up Sequence in QDR-II+ SRA

During power up, when the DOFF is tied HIGH, the DLL gets
locked after 2048 cycles of stable clock. QDR-II+ SRAMs must
be powered up and initialized in a predefined manner to prevent
undefined operations.

Power Up Sequence

Apply power with DOFF tied HIGH (All other inputs can be
HIGH or LOW)

Apply V

DD

before V

DDQ

Apply V

DDQ

before V

REF

or at the same time as V

REF

Provide stable power and clock (K, K) for 2048 cycles to lock
the DLL

DLL Constraints

DLL uses K clock as its synchronizing input. The input must
have low phase jitter, which is specified as t

KC Var

The DLL functions at frequencies down to 120 MHz

If the input clock is unstable and the DLL is enabled, then the
DLL locks onto an incorrect frequency, causing unstable SRAM
behavior. To avoid this, provide 2048 cycles stable clock to
relock to the desired clock frequency

Power Up Waveforms

Figure 4. Power Up Waveforms

K

K

Fix HIGH (tie to VDDQ)

VDD/VDDQ

DOFF

Clock Start (Clock Starts after VDD/VDDQ is Stable)

Unstable Clock

> 2048 Stable Clock

Start Normal
Operation

~ ~

~ ~

VDD/VDDQ Stable (< + 0.1V DC per 50 ns)