Operation, Maintenance – PolarCool 36″ ZONE PolarCool™ Fan User Manual

Page 7

Advertising
background image

Manual No. 4801-6404 Rev 8-10

PolarCool

Page 7 of 15

FIGURE C

5.3 Shut Down

When you are finished with the PolarCool Zone, follow these steps for shutting down the unit.

1.

Turn off pump.

2.

Wait ten to fifteen minutes (This will dry the pad and minimize algae growth).

3.

Turn off fan.

4.

Disconnect water and power to the unit.

5.

If water is not disconnected, turn off water supply to PolarCool whenever PolarCool is not in use.

6.

Operation

6.1 Ventilation is Very Important


Fresh air is very important for proper operation of evaporative cooling. Ventilation can be provided by air flow
from open windows and doors, or exhaust fans. Positioning the PolarCool intake close to an open door is a common
way to assure fresh air. Evaporative cooling will not function properly in a closed environment.

6.2 Normal Operation

Under normal conditions, the pump should run constantly when air is being drawn through the pads. If outside
conditions are not warm enough to run evaporative cooled air, an alternative is to run the fan
with the pump off.
Dry the pads completely each night by turning off the pump and drawing air through the pads with the fan.

7.

Maintenance

7.1 Maintenance Accessibility


Since evaporative coolers require maintenance, the PolarCool Zone has been designed to make maintenance as easy
as possible. By simply removing the pad cover plates and the pads, basically all critical parts are within easy reach
for inspection, including the pads, spray bar, pump, strainer, and water reservoir. To open, see figure on the next
page.

Low Water Level Switch

Full Level Switch

Solenoid Valve