NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR

WHILE CONNECTED TO A FUEL SOURCE

© 2013, Pinnacle Products International, Inc.

Propane Tank Top Heater User’s Manual

®

Operation

3URSDQH6XSSO\,QIRUPDWLRQ

3URSDQH /3

This heater is not supplied with a propane cylinder.
Use only an approved propane cylinder.

/3&KDUDFWHULVWLFV

–

Flammable, explosive under pressure, heavier
than air and pools in low areas.

–

In its natural state, propane has no odor, but
for your safety an odor that smells like rotten
cabbage has been added.

–

Contact of propane (LP) gas with the skin can
cause freeze burns.

–

Heater is manufactured for use with propane
gas only. DO NOT attempt to convert to any
RWKHUJDV6XFKPRGL¿FDWLRQVDUHGDQJHURXV
and will void the warranty.

–

When heater is not in use, LP Cylinder must be
turned OFF.

–

Be sure that the LP Cylinder is located on a
level and stable surface.

–

DO NOT use this heater in a basement or
below ground level. Propane is heavier than
air and will always seek the lowest level. If you
suspect a leak, shut off the valve at the LP
Cylinder immediately.

7KH3URSDQH /3 F\OLQGHUPXVWDOVREH
HTXLSSHGZLWKWKHIROORZLQJ

–

A collar to protect the gas valve.

–

A shut-off valve terminating a LP cylinder valve
RXWOHWDVVSHFL¿HGLQWKH$PHULFDQ1DWLRQDO
Standard for Compressed Gas Cylinder Valve
Outlets and Inlets Connections.

–

A safety relief valve having direct
communications with the vapor space of the LP
cylinder.

–

The heater must operate on vapor withdrawal
from the operating cylinder.

–

7KHDPRXQWRI3URSDQH /3 XVHGZLWKWKLV
KHDWHUYDULHV%RWKIDFWRUVDUH

–

The amount of gas in the cylinder of LP.

–

The temperature of the LP tank and its
surroundings.

–

Always keep LP cylinder fastened and upright.

–

Avoid tipping the LP cylinder on its side when
connected to a regulator, since this may
cause damage to diaphragm in the regulator.

–

Handle valves with care.

–

Never connect an unregulated LP cylinder to
a construction heater.

–

DO NOT subject LP cylinder to excessive heat.

–

Tightly close the gas shutoff valve on the LP
cylinder after each use.

–

$OO¿WWLQJVPXVWEHSURWHFWHGZKHQ
disconnected from the LP cylinder.

–

Never store an LP cylinder inside a building or
in the vicinity of an gas burning appliances.

3URSDQHLVVDIHWRXVHZKHQ
properly handled. Careless

KDQGOLQJRIWKH/3F\OLQGHUFRXOGUHVXOWLQD

ILUHDQGRUDQH[SORVLRQ

CAUTION

7KHGLVFRQQHFWHGWDQNPXVW

QHYHUEHVWRUHGLQDEXLOGLQJ

garage or any other enclosed area.

CAUTION