Troubleshooting – RearviewSafety RVS-770613 User Manual

Page 22

Advertising
background image

REAR VIEW SAFETY

22

Troubleshooting

Monitor Displays Blue Screen & Displays No Signal

Do a hard reset, unplug all

cables and power cables from

multiplexer (silver box) leave

out for 1 minute and then

re-connect them.

Check to ensure that the con-

nection to the camera is tight.

Verify camera cable is plugged

into port labeled Backup Camera

Verify that the blue positive

trigger on power harness is

put to power 12v+.

If the problem still persists, ver-

ify that alternate ports work. If

alternate ports do not work, re-

move Blue Trigger wire from

12V+ and select alternate chan-

nels.

Monitor Will Not Power-Up (no backlight on power button)

Check fuse

Check 12v+ to monitor

Check ground connection

No Image On Screen

Verify camera is on correct

camera input

Verify cable is connected to

monitor

Verify camera is connected to

cable

Connect known working

camera and cable to monitor.

Verify Blue trigger is receiving

power

Audio on Camera

Verify chosen camera has audio

Verify volume setting

Confirm that the Blue audio

trigger is connected to 12v+

Advertising