8

step

p r e pa r i n g t o b u ry c o r e

r e i n s e rt i n g c o r e i n t o c o v e r

7

step

You are now ready to put core back into cover

from Mark T to Point X. Insert fid at Mark T, jam the

taped core end tightly into end of fid. With pusher,

push fid and core around to, and through opening

at Point X (exactly where core was first extracted.)

When using wire fid, attach fid to taped core. After

fid is on, milk braid over fid while pulling through

from Mark T to Point X.
Depending on eye size, fid may not be long enough

to reach from Mark T to Point X in one pass. If not,

bring fid out through cover, pull core through and

reinsert fid into exact hole it came out of. Do this as

many times as needed to reach Point X.

Next, pull on core tail coming out at Point X,

then on tapered cover coming out at Mark 3,

the crossover should be tightened until opening

in crossover is approximately equal to diameter

of rope. Hold the loop at the crossover with one

hand. With other hand firmly smooth towards

Point X in one direction, and towards Mark 3

in other direction. Remove all cover slack.

Tapered cover will disappear at Mark 3. Then cut

core tail off close where it comes out at Point X.

r

x

For large eye reinsert fid

and core at same point it

comes out

Fid and end of core

comes out at

X

Insert core into

cover at

Point T

mark 3

mark 2

mark 1

core

cover

Cut core after smoothing from

T

crossover

crossover

mark t

r

Hold here

mark 2

Smooth

Tapered cover must
disappear inside
here

Pull to tighten crossover
then smooth from

T

to bury inside core

cover

core

x

Beginning at slipknot, milk cover

by sliding hand toward loop

mark 3

mark 2

mark t

r

x

cover

Milk cover until

core is buried

to here

9

step

b u ry i n g t h e e x p o s e d c o r e

Hold rope at slipknot and with

other hand milk cover toward

splice, gently at first, then more

firmly. Cover will slide over Mark 3,

Mark 2, the crossover, and Point R.
Then smooth loop from Mark T

to Point X removing all slack.

Continue milking until all cover

slack between knot and throat of

eye has been removed.

10

step

Now untie the slipknot. If eye is not the right size, carefully check Steps 1 through 9.
If a hollow spot appears at the throat this means that the core tail was cut too short. Do not worry

as this does not affect the splice performance nor its strength. Reason: the total load of an eye

splice is split between the two legs. Therefore, each side of the splice only has to support 50%

of the total load. The braided cover alone can handle this load factor.
You should whip the eye splice

starting at base of throat

of eye, especially if rope is 1"

diameter and larger.

End of buried section

Crossover point is buried here

Tail of core

disappears

here

whipping

f i n i s h i n g t h e s p l i c e

Finished splice