Sony TC-KE400S User Manual

Page 9

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Adjusting Bias and Recording

Level Calibration

Automatically

(unavailable on the TC-KE200)

Since there are many different types of cassettes on the
market, your tape deck automatically sets the
appropriate equalization characteristics and bias
current for each tape type (ATS: Automatic Tape
Selection). However, you can get better recording
results by doing the automatic bias current and the
recording level calibration.

SONY

|l

|v|

1 1

c

D

4

CE) S

Q O

1

insert the cassette you want to record on.
Make sure the record-protect tabs on the cassette
have not been removed.

2

Press AUTO CAL until "CAL" appears in the

display.

Note

If the record-protect tab for that size has been removed

(see page 11), "AUTO CAL" in the display flashes three

times and automatic calibration cannot be performed.

3

Press II PAUSE to start the automatic calibration

procedure.
The automatic calibration procedure starts (i.e.,
recording test tones, rewinding, and playing
back).
During the calibration, the counter changes from
9 to 0.

4 Start the actual recording (see page 6).

To cancel the automatic calibration function
Press

If "AUTO CAL" flashes continuously

The automatic calibration procedure has been interrupted

by:

— The end of the tape. Turn the cassette over or rewind the

tape to a new position that allows recording of the test

tone.

— Damaged tape or dirty heads. Change the cassette or

clean and demagnetize the heads (see page 11).

Updating the calibration setting

As long as the tape deck stays on, calibration data are
saved and called up each time you insert a cassette of
the same type (I, II or IV). "AUTO CAL" appears in
the display when you insert a cassette to indicate that

calibration data for that tape type exists. However, we
recommend that you repeat the automatic calibraion
procedure each time you insert a new cassette since
cassettes of the same type also vary in their
characteristics. Before recalibrating, be sure to clear the
existing calibration data by pressing AUTO CAL until

"AUTO CAL" disappears from the display. Then start
from Step 2 of the automatic calibration procedure.

When the automatic calibration procedure ends,
the tape rewinds to the original position, the
counter returns to normal and the tape deck
stops.

Advertising