Installation requirements – LG 4000 User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Requirements

X

The recommended mounting height for the iCAM4000 is 142cm (56 inches) from the floor to the bottom of the

unit. This mounting height can be adjusted to accommodate the height of the average user at the installed location.

High amounts of ambient light must be avoided. Intense light sources such as sunlight or halogen lamps may
reduce the image capture performance of the iCAM, this may result in an increased "failure to acquire" rate.

The iCAM is not weatherproof and must not be exposed to precipitation or extreme temperatures. An enclosure

may be used to protect the unit if required. See www.lgiris.com - Support & Service for more information.

All system components including the Ethernet network must be powered through Uninterruptible Power Supplies

(UPS). UPS must provide power line filtering as well as power back-up operation.

Each IrisAccess'T'^ system component on the Ethernet network system must have a unique manually assigned IP

address.

The iCAM4000 requires at least the following wires:

• Ethernet network wiring to connect with the network switch to communicate to the IrisServer or an ICU.

* Note: For systems consisting of only an IrisServer and iCAM may use an Ethernet crossover cable to connect

the iCAM directly to the IrisServer computer.

• Power (12VDC +/-10% and 2.5Amps MAX)

IMPORTANT: IT IS RECOMMENDED TO USE THE POWER ADAPTER SUPPLIED WITH THIS PRODUCIAN OVER OR
UNDER VOLTAGE APPLIED TO THIS PRODUCT MAY CAUSE PERMANENT DAMAGE AND VOID THE WARRANTY.

Advertising