OPERATION

STOPPING THE ENGINE

e Unplug all electrical loads from the generator panel

receptacles, Never start or stop the engine with elec»
trical devices plugged in and turned on.

Let engine run at nodoad tor several minutes to stabi­

lize the internal temperatures of engine and generator.

Set the Engine RunXStop Switch to STOP Wait for

engine to come to a complete stop (Fig 7)

Close the Fuel Shutoff Valve (Fig, 5),

BATTERY SAFETY

A

A

A

EXPLOSIVE HYDROGEN GAS
CAUTION: Storage batteries give off EXPLOSIVE
hydrogen gas while charging. An explosive mix­
ture will remain around the battery for a tong time

after it has been charged. The slightest spark can
ignite the gas and cause an explosion. Such an
explosion can shatter the battery and cause blind­
ness or other serious injury.
CAUTION: DO NOT permit smoking, open flame,

sparks or any source of heat around a battery. DO
NOT use any lighter or other flame to provide
lighting for checking battery fluid levels. Wear
protective goggles, rubber apron and rubber
gloves when working around a battery.

CAUSTIC SULFURIC ACID
CAUTION: Battery electrolyte fluid is an extremely

caustic sulfuric acid solution that can cause severe
burns. DO NOT permit fluid contact with eyes,
skin clothing,, etc. If spillage occurs,flush with
Clearwater immediately.

CHARGING A BATTERY

Your generator has the capabillly of recharging a dis­

charged. 12-volt automotive or utility style storage battery

Do not use the unit to charge any 6-volt batteries. Do not
use the unit to crank an engine having a discharged battery

To recharge 12-vo(t batteries, proceed as follows:

» Check fluid level in all battery cells. If necessary, add

ONLY distilled water to cover separators in battery

f'ollc* nn

I ICP TAP \A/ATPD

C8MS L/L/ fNw I UDtl i M I ^ V V A I C n

If the battery is equipped with vent caps, make sure

they are installed and are light

*

It necessary, clean battery posts or terminals

» Connect battery charge cable connector plug to panel

receptacle (Fig 9). identified by the words "12-VOLT
D.C”

® Connect battery charge cable clamp with red handle to

battery post or terminal indicated by a POSITIVE, POS
or (+).

*

Connect battery charge cable clamp with black handle
to battery post or terminal indicated by a NEGATIVE,
NEG, or (—)

» Start engine (see "Starting the Engine” on Page 5) Let

the engine run while battery recharges

When battery has charged, shut down engine (see

"Stopping the Engine" on this page)

NOTE: Use an automotive hydrometer to test battery state
of charge and condition. Follow the hydrometer manufac­
turer’s instructions carefully Generally, a battery is consid­

ered to be at 100% state of charge when specific gravity of
its fluid (as measured by hydrometer) is 1,260

ppf^TPr'TlV/P nPVir'PCi

« fi V«/ I C

m

I I V C

m

Cr C

m

V I

v

'C

m

LOW OIL PRESSURE SHUTDOWN

A Low Oil Pressure Shutdown switch (Fig 10) on the
engine monitors low oil pressure The switch is normally
ciosed (N.C), and is held open by engine oil pressure
during startup and operation Should engine oil pressure
drop below a safe value during operation, an automatic
shutdown occurs This feature protects the engine against
damaging low oil pressure conditions and possible engine
failure.

If the engine shuts down unexpectedly, check engine oil
level before attempting a restart.

A

CAUTION!: DO NOT ATTEMPT TO OPERATE AN
ENGINE WITH LOW OIL PRESSURE BY UNPLUG­
GING THE LEAD FROM THE LOW OIL PRESSURE

SWITCH OR BY BYPASSING THE SWITCH IN ANY
MANNER. OPERATING WITH LOW OIL PRES­
SURE COULD DAMAGE THE ENGINE OR CAUSE

FAILURE.