Specifications, Glossary, Duty cycle – Craftsman 921.166400 User Manual

Page 4: Idjj

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

important Safety instructions & Guidelines

Risi c of Breati ling

Avoid using the air compressor in confined areas. Always have adequate space
(12 inches) on all sides of the air compressor. Also keep children, pets, and others out
of the area of operation. This air compressor does not provide breathable air for anyone
or any auxiliary breathing device. Spraying material will always need to be in another
area away from the air compressor to not allow intake air to damage the air compressor
filter.

Eie

Risk of

ctrical Shi

idjj

ick

Never utilize the air compressor in the rain or wet conditions. Any electrical issues

or repairs should be performed by authorized personnel such as an electrician and
should comply with all national and local electrical codes. The air compressor should
also have the proper three prong grounding plug, correct voltage, and adequate fuse
protection.

Exp

Risk of

losion or Fire

Never operate the compressor near combustible materials, gasoline or solvent vapors.
If spraying flammable materials, locate the air compressor at least 20 feet away from

the spray area. Never operate the air compressor indoors or in a confined area.

Ris k of Burst

\JL

j

¡ng

Always drain the air compressor tank daily or after each use. If the tank develops a leak,
then replace the air compressor. Never use the air compressor after a leak has been
found or try to make any modifications to the tank. Never modify the air compressor’s
factory settings which control the tank pressure or any other function.

Specifications

Pump.................................................... Oil-lube direct drive
Motor...................................................... 1.0 HP (Induction)
Bore.............................................................................. 1.65"
Stroke........................................................................... 1.26”

Voltage Single Phase............................................. 120 VAC

Minimum Circuit Requirement................................15 Amps

Glossary

CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure

for air delivery.

PSIG: Pounds per square inch gauge; a unit of measure

for pressure.

ASME: American Society of Mechanical Engineers.
California Code: Unit may comply with California Code

462 (I) (2)/ (M) (2).

Cut-In Pressure: The air compressor will automatically

start to refill the tank when the pressure drops
below the prescribed minimum.

Duty Cycle

Air Tank Capacity............................................... 12 Gallons
Cut-in Pressure......................................................... 95 PSI
Cut-out Pressure.......................................................125 PSI
SCFM @ 90 PSI............................................................... 2.4
Oil Capacity.................................................. 90 ml or 3 oz.
Oil Type................................................ SAE 30 Non-detergent

Cut-Out Pressure: The point at which the motor stops

when the tank has reached maximum air
pressure.

Code Certification: Products that bear one or more of

the following marks: UL, ULc, ETL, CSA, have
been evaluated by OSHA-certified independent
safety laboratories and meet the applicable

Underwriters Laboratories Standards for Safety.

This is a 50% duty cycle air compressor. Do not run the air compressor more than 30 minutes of one hour. Doing so
could damage the air compressor.

Advertising