Before using your spray gun – Craftsman 919.155190 User Manual

Page 9

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

AWARNING

USE OF A FACE
MASK ES

RECOMMENDED TO PREVENT EN-
HAU«-fON OF TOXEC MATERIAL.

2

.

Horizorstal position

Vertical position

Turn fEuid control knob clockwise

until it stops, do not force. This

will shut off the fluid flow. NOTE:
The fluid or density of “tan spray”

is controlled by fluid control
knob.

3.

ACAUTION

first thread flush pattern

'^r

^Control

Knob

Ruid

^i^sponbol

Knob

4. Turn air valvo control knob

clockwise until it stops, do not

force.

Before Using Your Spray

Gun

1. Set up spray gun as described

in the "How to Set Up Spray
Gun" paragraph in the

“Assembly' section of this

manual.

To Use Spray Gun

1. The position of the air cap fioms

will deteimine the fan spray

pattern. Loosen air cap and rotate
horns to achieve desired pattern.

Tighten air cap.

ACAUTION

ACAUTION

Turn pattern conb'ol knob

counterclockwise until first thread
is flush with gun body. NOTE: Air

flow is controlled by pattern con­
trol knob.

DO NOT turn pattern
control knob or fluid

control knob counter clockwise after
first thread is flush with the gun
body. They are under pressure vrtien

the gun is triggered and could leave
the gun wilb force.

ACAUTION

5. Adjust air pressure to 40 psi at

regulator.

DO NOT exceed 45

psi.
Pressure may vary

according to

viscosity of material used. Maximum

working pressure of gun is 45 psi.

DO NOT EXCEED PRESSURE LIMIT

OF GUN OR ANY OTHER COMPO­

NENT IN SYSTEM!

6.

Depress spray gun trigger and

gradually turn the fluid control

knob counterclockwise until

desired fluid flow is reached.

Trigger gun quickly, one second

on-off to test pattern.

NEVER point Spray

gun at self or any

other person. Accidental discharge
of material may result in serious

injury.

To adjust spray pattern and fluid
presaire:

To adjust the fluid, turn fluid con­

trol knob counterciockwise to in­

crease or clockwise.

To adjust the air flow, turn pattern

control knob counterclockwise to

increase or clockwise to de­

crease.

To fine tune the air flow, turn air

valve control knob counterclock­
wise to increase, or clockwise to
decrease.

IMPORTANT: Always Clean gun after

each use. See 'Maintenance" section

for correct procedure.

9- ENG

D29783