7. Rotate the blade bringing the marked tooth to the

rear and about I

/2

in. above the blade.

8. Carefully slide the combination square to the rear

until the ruler touches the marked tooth.

9. If the ruler touches the marked tooth at the front and

rear position, no adjustment is needed at this time.
If not or the base of the rule is no longer parallel

with the edge of the miter gauge groove, perform
adjustment procedure described in next section.

Fig. R

Fig.S

ADDITIONAL BLADE ADJUSTMENTS {FIG. S)
NOTE:
The adjusting lock nuts are 8 mm.
The adjusting mechanism is located above the blade
height adjusting hand wheel under the tabletop. If the
front and rear measurements are not the same.

If the blade is partial to right side:

1. Loosen the two lock nuts (1) and turn the left

adjustment screw (2) counterclockwise, then adjust
the right side adjustment screw (3) clockwise.

2. Remeasure, as described in steps 4 to 9 in the

prior section.

3. When alignment is achieved, turn the left adjustment

screw (2) until it touches the pivot rod (4) then tighten
both lock nuts (1).

If the blade is partial to left side:

1. Loosen the two lock nuts (1) and turn the right

adjustment screw (3) counterclockwise, then adjust
the left side adjustment screw (2) clockwise.

2. Remeasure, as described in steps 4 to 9 in the

prior section.

3. When alignment is achieved, turn the right

adjustment screw (3) until it touches the pivot rod (4)
then tighten both lock nuts (1).

BLADE TILTING INDICATOR (FIG. T)
1. When the blade is positioned at 90°, adjust the blade

tilt pointer to read 0° on the scale.

2. Remove the magnifier, position the pointer over 0°

and replace the magnifier.

Fig.T

MITER GAUGE ADJUSTMENT (FIG. T-1)

1. Loosen the lock handle (1) to allow miter body (2) to

rotate freely (Fig. T-1). Position the miter body at
90° so the positive detent secures its position.

Tighten the lock handle to hold the miter body in
position.

2. If the pointer (3) requires adjustment, loosen the

screw under the pointer with a hex key. Adjust the
pointer to 90° on the scale then firmly tighten the
adjustment screw.

3. To change angles on miter gauge, loosen the lock

handle (1) and rotate the miter body to desired angle
as indicated by the scale. Secure in position by
tightening the lock handle.

Fig. T-1

2

1

3

16