Specifications, Software driver, Conformance – CH Tech EM405D100 User Manual

Page 2: Ordering information

Advertising
background image

Rev. *

Specifications:

Implementation:

• All versions use either two (2), four (4) or eight (8)

ANSI/VITA Standard 16 Channel M-Modules
(MA203), each of which have the block diagram
shown above

• See the EM405D and EM405-8 on C&H web site for

further information on the instrument enclosure
mounting and dimensions.

Trigger/Sample Strobe Features:

• An external clock may be routed through one

mezzanine to a carrier trigger and back to the Event
Detector triggers to minimize skew between
channels

• One mezzanine’s clock may be used as a master in

a similar manner

External Trigger Inputs:

• 32 Channel Unit

TTL

• 64 & 128 Channel Units

TTL and LVDS

External Power (32 Channel Unit):

• AC Input 100 to 240VAC, 47 to 63Hz with furnished

adapter

• Alternatively DC powered by 12V, 1A

External Power (64 and 128 Channel Units):

• AC Input 85 to 265VAC, 47 to 63Hz
• Alternatively DC Powered by 36 to 75V

Software Driver:

• Windows DLL
• Soft Front Panel Executable
• Online Help
• LabWindows/CVI Function Panels
• ANSI-C Source Code
• LabView

Conformance:

• These modules will be CE compliant for Emissions,

Immunity and Safety

Ordering Information:

32 Channel Event Detector:

Model EM405D100

P/N 11030010-0001

64 Channel Event Detector:

Model EM405-8x106

P/N 11030010-0002

128 Channel Event Detector:

Model EM405-8x107

P/N 11030010-0003

DEBOUNCE

M-MODULE

I/F

TIMER

31-BIT

SAMPLE

AND

STORE

LOGIC

FIFO

RESET

PROGRAM

TRIGGER A OR B

EXTCLK

MEMORY

48-BIT

CONTROL

STORE

FRONT

PANEL I/O

WATCH

MASK

CLOCK

10KHz

- 5MHz

INTERRUPT

LOGIC

PROGRAM

CONTROL

RUN

SCLK

TRIGGER A OR B

SW

EXTRUN

SIGNAL

CONDITIONING

ACCESSORY

MODULE

ISOLATED

DC-DC

CONVERTER

INTERRUPT

PRESCALER

TRIGGER A OR B

INPUT

SIGNALS