Installation Step 9

Electrical Requirements

To reduce the risk of electric shock, your garage
door opener has a grounding type plug with a third
grounding pin. This plug will

onlyiW

into a grounding

type outlet.

If the plug doesn't fit into the outlet you have,

contact a qualified electrician to install the proper
outlet.

To avoid installation difficulties,

do not run the opener at this tim e.

To prevent electrocution or fire,

installation

and wiring must be in compliance with local
electrical and building codes.

Do

NOT

use an extension cord, 2-wire adapter,

or change the plug in any way to make it fit
your outlet.

Right

Wrong

If permanent wiring is required by your local code, refer to the following procedure:

To prevent eiectm cution,

remove power from

the garage door opener

and irom

the circuit

you plan to use for the permanent connection.

To make a permanent connection through the
7/8" diameter hole in the top of the opener
(according to local code):

• Remove the opener cover screws and set the

cover aside.

• Remove the attached 3-prong cord.

• Connect the black (line) wire to the screw on the

brass terminal; the white (neutral) wire to the
screw on the silver terminal; and the ground wire
to the green ground screw.

The opener m ust be

grounded.

Reinstaii the cover.

To avoid installation difficulties,

do not run the opener at this tim e.