Configuration and load (ohms), Max. average power at 0.1% thd (see note 2), 40 ms tone burst watts at < 0.05% thd (see note 4) – Crown Audio D-75A User Manual

Page 16: Eia watts at 1% thd (see note 5), 20hz-20khz, 1 khz, 20 hz, 50 hz, Dual (both channels driven), Bridge-mono (balanced output)

Advertising
background image

D Series Power Amplifiers

page 16

Operation Manual

D-45

Configuration and Load

(ohms)

FTC Continuous

Average Power at 0.1% THD

(See note 1)

Max. Aver-

age Power at

0.1% THD

(See note 2)

Single-Cycle Tone Burst

Watts at < 0.05% THD

(See note 3)

40 mS Tone Burst

Watts at < 0.05% THD

(See note 4)

EIA Watts at

1% THD

(See note 5)

20Hz-20kHz

1 kHz

1 kHz

20 Hz

50 Hz

1 kHz

20 Hz

50 Hz

1 kHz

1 kHz

Dual

(both channels

driven)

4

35

40

50

75

55

60

60

35

8

20

25

25

25

30

35

40

40

40

25

16

20

20

20

20

20

20

20

20

20

20

Bridge-Mono

(balanced output

)

8

70

85

105

145

85

85

85

70

16

40

50

50

50

60

70

50

50

55

50

6 Specifications

D-75A

Configuration and Load

(ohms)

FTC Continuous

Average Power at 0.1% THD

(See note 1)

Max. Aver-

age Power at

0.1% THD

(See note 2)

Single-Cycle Tone Burst

Watts at < 0.05% THD

(See note 3)

40 mS Tone Burst

Watts at < 0.05% THD

(See note 4)

EIA Watts at

1% THD

(See note 5)

20Hz-20kHz

1 kHz

1 kHz

20 Hz

50 Hz

1 kHz

20 Hz

50 Hz

1 kHz

1 kHz

Dual

(both channels

driven)

4

45

50

55

65

85

120

65

70

70

55

8

35

40

40

45

50

60

45

45

45

40

16

25

25

25

25

30

30

25

25

25

25

Bridge-Mono

(balanced output

)

8

95

105

110

140

165

235

140

140

140

105

16

70

75

80

90

100

130

90

90

95

75

Figure 6.1 D-45 Power Matrix

Figure 6.2 D-75A Power Matrix

Notes:

All power matrix specifications are based on a 0.1% regulated 120 VAC, 60 Hz power mains and an ambient room temperature of 70° F (21° C).

1. Continuous power in the context of Federal Trade Commission testing is understood to be a minimum of five minutes of operation. Harmonic distortion is measured at the RMS sum total as a percentage of the fundamental output voltage. This applies for
all wattages greater than 0.25 watts.
2. A 1 kHz sine wave is presented to the amplifier and the output monitored for nonlinear distortion. The level is increased until the THD reaches 0.1%. At this level the average power per channel is reported.
3. A single cycle sine wave is presented to the amplifier and monitored for nonlinear distortion. The average power during the burst is reported. Loudspeakers must be able to withstand this level if they are to be safely used with this amplifier.
4. A 40 millisecond burst or a two cycle sine wave (whichever is of greater duration) is used and the power computed as the average power during the burst. The duty cycle of this test is 10 percent. This power level is a measure of how loud an amplifier is
as perceived by the human ear.
5. EIA standard RS-490 (both channels driven).