background image

CY7C1411BV18, CY7C1426BV18

CY7C1413BV18, CY7C1415BV18

Document Number: 001-07037 Rev. *D

Page 21 of 30

I

DD

[21]

V

DD

Operating Supply

V

DD

= Max,

I

OUT

= 0 mA,

f = f

MAX

= 1/t

CYC

200MHz

(x8)

620

mA

(x9)

620

(x18)

655

(x36)

715

167MHz

(x8)

535

mA

(x9)

535

(x18)

565

(x36)

615

I

SB1

Automatic Power down
Current

Max V

DD

,

Both Ports Deselected,
V

IN

≥ V

IH

or V

IN

≤ V

IL

f = f

MAX

= 1/t

CYC

,

Inputs

Static

300MHz

(x8)

370

mA

(x9)

370

(x18)

370

(x36)

400

278MHz

(x8)

355

mA

(x9)

355

(x18)

355

(x36)

370

250MHz

(x8)

355

mA

(x9)

355

(x18)

355

(x36)

370

200MHz

(x8)

300

mA

(x9)

300

(x18)

300

(x36)

300

167MHz

(x8)

270

mA

(x9)

270

(x18)

270

(x36)

270

AC Electrical Characteristics

Over the Operating Range

[13]

Parameter

Description

Test Conditions

Min

Typ

Max

Unit

V

IH

Input HIGH Voltage

V

REF

+ 0.2

V

V

IL

Input LOW Voltage

V

REF

– 0.2

V

Electrical Characteristics

(continued)

DC Electrical Characteristics

Over the Operating Range

[14]

Parameter

Description

Test Conditions

Min

Typ

Max

Unit