6 Management mode

38

B225 User instructions

PC protocol

A PC can be connected to the serial port of the scale. The PC
can then act as a remote terminal to control the scale, and
display scale / weight information.

To set up the scale for PC protocol you must first configure
the following:

Serial port configuration- Branch 36 on page 33

Printer configuration - Branch 38 on page 34

PC protocol commands and codes
The scale’s RS-232 bidirectional communication works in a
server/client protocol. A computer server sends a command
code to the scale (client) which will return a response to the
server device or perform a scale function. Commands to the
scale are in uppercase, terminated with a carriage return.
Scale responses begin with the lowercase equivalent of the
command code.

COMMAND

RESPONSE

DESCRIPTION

CA<CR>

none

Clear Sample

CC<CR>

cc_xxxxx<CR>

Request piece count

CP<CR>

cp_xxxxxx_uu<CR>

Request piece weight value

CM<CR>

none

Switch to count mode

DIxxxxxxxx<CR>

none

Display message xxxx

(message is 8 characters max)

IC<CR>

none

Reset Scale (warm start)

PWx.xxxxx_uu<CR> none

Loads xxsx.x as piece weight

TR<CR>

tr_x.xxx_uu<CR>

Request tare value

TZ<CR>

none

Clear the current tare

Txxxx.x_uu<CR>

none

Loads xxxx.x as tare

WD<CR>

ws_x.xxxx<CR>

Request net weight

WE<CR> we_x.xxx_uu<CR>

Request net weight with units

Advertising