Error codes – Salter Brecknell 6720 User Manual

Page 23

Advertising
background image

Model 6700 Family User’s Manual

23

Error Codes

The 9-pin version of the 6700 has DE type
female connector accessible at the rear of the
unit. The functional pinout of this connector is
compatible with a standard PC with a pass-
through cable.

DE-9 Female Scale

DE-9 Male Host

Pin Name Direction Pin Name Direction

1.

JMP 1

-

1.

DCD

IN

2.

TXD

OUT

2.

RXD

IN

3.

RXD

IN

3.

TXD

OUT

4.

JMP 1

-

4.

DTR

OUT

5.

SG

-

5.

GRD

-

6.

JMP 1

-

6.

DSR

IN

7.

JMP 2

-

7.

RTS

OUT

8.

JMP 2

-

8.

CTS

IN

9.

NC

-

9.

RI

IN

Any system errors detected by the scale will be
displayed as the letter E followed by a two-digit
error code. Press the TEST key to continue
operation. If a calibration error occurs, the only
way to clear it is by recalibrating the scale.

The error codes are broken down into two
hexadecimal numbers, with each bit defining a
single error condition. The error codes are
defined as follows:

RS-232 Interface

* Jmp1 and Jmp2 pins
are connected
internally on the scale
PCB connector.

Advertising
This manual is related to the following products: