(4) Command: T<CR> (54h 0dh)

Response: TARE function is activated, and then returns scale status. just like
pressing TARE button:
<LF>

H1H2H3

<CR><ETX>

If TARE function cannot be activated, it will return to current scale status.

(5) Command: U<CR> (55h 0dh)

Response: Changes units of measure and return scale status with new units,
just like pressing UNIT button. The new measure unit should be allowed to
use as per P11 setting.
<LF>u1u2<CR><LF>

H1H2H3

<CR><ETX>

If the weight unit is lb:oz, U1U2= lb oz

(6) Command: L<CR> (4ch 0dh)

Response: If Hold function can be activated, it will enable/disable hold (lock)
function, like the HOLD key is pressed, and returns scale status.
<LF> H1H2H3 <CR><ETX>

(7) Command: X<CR> (58h 0dh)

Response: power off the scale, just like press down the ON/OFF key to turn
off the scale.

(8) Command: all others

Response: Unrecognized command
<LF>? <CR><ETX>

2.5) Output status bit meaning:

Table5: The status bits definition:

Bit

Byte 1 (H

1

)

Byte 2 (H

2

)

Byte 3 (H

3

)

0

0=stable

0= not under capacity 01=normal work mode

10= hold work mode
00=not define
11= not define

1= not stable

1= under capacity

1

0= not at zero point 0= not over capacity

1= at zero point

1= over capacity

2

always 0

always 0

0= gross weight

1= net weight

3

0= eeprom OK

always 0

always 0

1= eeprom error

4

always 1

always 1

always 1

5

always 1

always 1

always 1

6

always 0

always 1

always 0

7

parity

Parity

parity