Notes:

*When the ArrowStik® Left and ArrowStik Right wires are both connected to +power, the Center-Out ArrowStik function is activated.

**When the Pattern Select wire is connected to +power and all other inputs are off, test mode is enabled to exercise all outputs in

sequence until +power is removed from the wire.

The priority for the 3-Level inputs is L3, L2 then L1 in that order. In other words, if power is applied to both the L1 and L2 inputs, the

L2 function will be enabled.

If the light bar is equipped with Steady Burning light heads, these heads are enabled with the 3-Level input wires. The jumper

plug must be moved to JP1, JP2 or JP3 to select the 3-Level input which will enable the Steady Burning heads, (see Figure 6).

The Steady Burn function for both the Take Down and Alley lights will always override the Wig/Wag Flash function.

The Cruise Light function is mutually exclusive with all other functions. If any other input has +power applied, the Cruise

Lights will be turned off. Light bars with software T116XXV6 or greater, T117XXV6 or greater or T118XXV2 or greater can

operate the Cruise Light Function and the Dim Function together. The Dim Function has no affect on the Cruise Lights.

Step 3

Continue applying +power to the GRN/BLK wire. Scroll to the next flash pattern by momentarily holding the Pattern Select wire (BLK/

RED) to +power for ~1 second, until the light heads switch flash patterns, and then releasing it. This will step to the next pattern in

numbered order as listed in Table 4 for the selected 3-Level mode. The new pattern is automatically stored each time. Repeat this

procedure for Level-2 and Level-3.

Table 4 - Flash Patterns - 21TR Plus

TM

Factory default

Lighting Level

Flash Pattern description

L1

L2

L3

Factory default Level 2 14

1

4

Fast Alternating Quad Flash

15

2

5

Alternating Two Flash

16

3

6

Alternating Single Flash

17

4

7

Fast Picket Fence Quad Flash

18

5

8

Slow Picket Fence Quad Flash

19

6

9

Alternate Quad Flash

20

7

10

Slow Alternating Six Flash

21

8

11

Alternating Six Flash

22

9

12

Variable Rate Even/Odd Flash

23

10

13

Alternating Quad Flash 75 FPM (NFPA)

Factory default Level 1 1

11

14

Fast Alternating Quad Flash (Rear Only)

2

12

15

Fast Even/Odd Quad Flash (Rear Only)

3

13

16

Alternating Quad Flash (Rear Only)

4

14

17

Slow Alternating Six Flash (Rear Only)

5

15

18

Variable Rate Even/Odd Head Flash (Rear Only)

6

16

19

Fast Alternating Quad Flash (Front Only)

7

17

20

Fast Even/Odd Quad Flash (Front Only)

8

18

21

Alternating Quad Flash (Front Only)

9

19

22

Fast Alternating Six Flash (Front Only)

10

20

23

Variable Rate Even/Odd Head Flash (Front Only)

Factory default Level 3 11

21

1

Cycle Flash (cycles through multiple patterns)

12

22

2

Simultaneous Quad Flash (all Light Heads) 75 FPM (NFPA)

13

23

3

Null Flash (no flashing light heads - only Steady Burns if equipped)

Advertising