5
IMPORTANT: To extend the power (+) and ground (-) wires, use the following as a guide.
1 to 10 ft. use 20AWG wire
10 to 50 ft. use 18AWG wire
Pattern Selection Timing
Time
Function
0~1 sec
NEXT PATTERN / ON
1~3 sec
PREVIOUS PATTERN
3~5 sec
P19 CYCLE FLASH
>5 sec
OFF
FIGURE B
4. For synchronized operation of multiple HB Series lights
the yellow wires from each unit's cable must be connected
together. Insulate this connection using an insulated butt splice
to prevent accidental contact with power or ground.
Connections:
Red
+Power (11-30VDC)
Black Ground
Yellow Synchronization
Blue Pattern Selection
The HB6PAK light should be fully inserted into the hole so
that the aluminum heatsink is against the light housing and
the grove of the rubber seal is locked into the hole. This will
provide a secure installation and a highly water resistant
seal.