T7 - +12VDC - Connect to the positive terminal of the battery with 30 Amp circuit protection. Locate the fuse or circuit

breaker at the battery and use size 10 AWG wire minimum. This terminal powers switches A,B & D only.

T8 - LEVEL 1, connect to the first level of warning lights (Green LED) position "1" on level switch.

T9 - LEVEL 2, connect to the second level of warning lights (Yellow LED) position "2" on level switch.

T10 - LEVEL 3, connect to the third level of warning lights (Red LED) position "3" on level switch.

T11 - +12VDC - Connect to the positive terminal of the battery with 30 Amp circuit protection. Locate the fuse or circuit

breaker at the battery and use size 10 AWG wire minimum. This terminal powers the 3-Level lighting control switch only.

NOTE: LEVEL 1, LEVEL 2, LEVEL 3, switch progressively. Switch position 1 provides +12 volts at terminal T8.

Switch position 2 provides +12 volts at terminals T8 & T9. Switch position 3 provides +12 volts at terminals T8,

T9 & T10.

SET-UP AND ADJUSTMENT

Make these adjustments and position the set-up switches prior to final mounting.

Audio Adjustments

PA/RRB Volume Adjustment - This is the main volume control located on the right side of the front panel. This control

sets the PA and RRB volume. Set the front panel volume control to the point that the PA volume from the siren speaker is

such that there is no feedback and the PA audio is intelligible.

Radio Rebroadcast Adjustment - Place the selector switch in the RADIO position. The MAX RRB trimmer located on the

rear panel of the siren and is accessible through the small hole labeled RRB. This control sets the maximum RRB level

that will reach with the front panel volume control. To adjust properly, set the volume knob fully clockwise and adjust the

RRB trimmer such that with the two-way radio volume inside the vehicle set to it's normal level, the the desired volume

level is produced outside the vehicle by the siren speaker.

Remote Input

The Remote input can be configured to activate in one of three modes: 1) Tri-State Input - accepts

a positive (+12V) signal or a ground (earth) signal, 2) Positive Only Input – accepts only a positive

(+12V) signal or 3) Ground Only Input – accepts only a ground (earth) signal. All 3600 series sirens

are factory set as a Tri-State Input. To reconfigure the Remote input to accept a Positive Only Input,

power up the siren while pressing the MANUAL button and holding it for approximately three (3)

seconds. When the MANUAL button is released the siren will be reconfigured to accept a Positive

Only Signal. To reconfigure the Remote input to accept a Negative Only Input, power up the siren

while pressing the AIR HORN button and holding it for approximately three (3) seconds. When the

AIR HORN button is released the siren will be reconfigured to accept a Negative Only Signal. To

restore the Remote input to the factory setting, power up the siren while pressing the MANUAL and

AIR HORN buttons and holding them for approximately three (3) seconds. When the MANUAL and

AIR HORN buttons are released the siren will be restored to the factory setting (Tri-State Input).

NOTE: The siren will not generate the MANUAL or AIR HORN tones during the configuration pro-

cess.