Troubleshooting – Code 3 XCEL User Manual

Page 9

Advertising
background image

9

Troubleshooting

(Refer to wiring diagram on page 15.)

PROBLEM

PROBABLE CAUSE

REMEDY

NO SIREN OUTPUT

A. PARK KILL ACTIVATED

B. SIRENLOCK ENGAGED

C. SHORTED SPEAKER OR SPEAKER

WIRES. (SIREN IN OVER CURRENT PRO-

TECTION MODE)

A. SHIFT VEHICLE OUT OF PARK.

B. SELECT PROPER SIRENLOCK LEVEL.

C. CHECK CONNECTIONS

EXTERNAL 20A FUSE BLOWS

A. AMPLIFIER POWER WIRES REVERSED

POLARITY

A. CHECK POLARITY

B. REPLACE SPEAKER(S)

NO OUTPUT FROM SPEAKER, TONES

HEARD INSIDE AMPLIFIER MODULE, SP

INDICATOR LIGHT OFF

A. SPEAKER NOT CONNECTED/ OPEN

CIRCUIT IN SPEAKER WIRING

B. DEFECTIVE SPEAKERS

A. CHECK SPEAKER WIRING

B. REPLACE SPEAKER(S)

SIREN TONES VOLUME TOO LOW/GAR-

BLED

A. LOW VOLTAGE TO SIREN AMPLIFIER

B. HIGH RESISTANCE IN WIRING/DEFEC-

TIVE SPEAKER

A. CHECK WIRING FOR BAD CONNEC-

TIONS/CHECK VEHICLE CHARGING

SYSTEM.

B. CHECK SPEAKER(S) WIRING/REPLACE

SPEAKER(S).

HIGH RATE OF SPEAKER FAILURE

A. HIGH VOLTAGE TO SIREN

B. 58 WATT SPEAKER CONNECTED TO 100

WATT TAP. 58 WATT NOT ALLOWED.

A. CHECK VEHICLE CHARGING SYSTEM.

B. USE CORRECT SPEAKER.

SIREN CONTINUES TO OPERATE FOR 7

SECONDS AFTER MANUAL BUTTON/HORN

RING IS RELEASED

A. “HIT-N-GO’ FEATURE ENGAGED. NOR-

MAL OPERATION

P. A. VOLUME LOW OR NO P. A. AT ALL.

A. INCREASE P.A. VOLUME.

B. MICROPHONE NOT COMPLETELY

PLUGGED IN.

C. DEFECTIVE MICROPHONE

D. INCORRECT MICROPHONE.

A. REFER TO SETUP AND ADJUSTMENT

SECTION

B. PLUG MICROPHONE IN SECURELY

C. REPLACE MICROPHONE

D. CALL CODE 3 FOR LIST OF ADAPTABLE

MICROPHONES.

RRB VOLUME LOW, OR NO RRB AT ALL.

A. INCREASE RADIO REBROADCAST

VOLUME.

B. RRB WIRES NOT CONNECTED TO TWO-

WAY RADIO EXTERNAL SPEAKER.

A. REFER TO SETUP AND ADJUSTMENT

SECTION.

B. CHECK RRB CONNECTIONS.

SIREN SOUNDS BY ITSELF

A. HORN RING WIRING FROM TERMINAL

REMOTE SHORTING TO POSITIVE OR TO

GROUND (EARTH).

A. CHECK WIRING FOR ANY SHORTING.

SIREN RUNS PROPERLY BUT SHUTS

DOWN WHILE RUNNING, THEN STARTS

RUNNING AGAIN AFTER A FEW MINUTES.

A. VEHICLE CIRCUIT BREAKERS NOT RAT-

ED PROPERLY, AND ARE OVERHEATING,

OR ARE NOT FUNCTIONING PROPERLY.

A. REFER TO SPECIFICATIONS SECTION,

PAGE 11. USE A BREAKER RATED AT 1.25

TIMES THE AMPERAGE OF THE EXPECTED

LOAD CURRENT.

ACTIVE AUXILIARY PUSH BUTTON LIGHTS

UP BUT LT LIGHT IS OFF.

A. ONE OR MORE OF THE AUXILIARY

FUSES HAVE BLOWN IN THE AMPLIFIER.

A. REPLACE THE FUSE(S) IN THE AMPLI-

FIER.

3 LEVEL SWITCH IS ACTIVE IN ANY LEVEL

BUT THE LT LIGHT IS OFF.

A. ONE OR MORE OF THE 3 LEVEL FUSES

HAVE BLOWN IN THE AMPLIFIER.

A. REPLACE THE FUSE(S) IN THE AMPLI-

FIER.

PA ONLY FUNCTIONS FOR 30 SECONDS

BEFORE TURNING OFF.

A. THIS IS NORMAL. THE PA IS TURNED

OFF AFTER 30 SECONDS TO AVOID THE

STUCK MIC POSSIBILITY.

A. SIMPLY RELEASE THE PTT BUTTON AND

PRESS AGAIN FOR ANOTHER 30 SECONDS

OF BROADCAST ABILITY.

RRB SHUTS OFF AFTER EXTENDED USE.

A. THIS IS NORMAL. THE RRB SHUTS OFF

AFTER AN EXTENDED PERIOD WHEN THE

EQUIPMENT STARTS TO OVERHEAT. THIS

IS TO AVOID DAMAGE TO THE COMPO-

NENTS IN THE AMPLIFIER.

A. ALLOW THE AMPLIFIER A FEW MINUTES

TO COOL DOWN.