Dynojet 224: Eddy Current Brake User Manual
Page 33

TO R Q U E M O D U L E I N S T A L L A T I O N
Load Cell Installation
Version 3
Model 224 Above Ground Eddy Current Brake Installation and User Guide
2-3
4
Secure the load cell to the mounting bracket using the two bolts and nuts
removed earlier.
5
Route the load cell cable out through the bottom panel opening. Make sure the
load cell cable is clear of any power cable or hot or rotating objects.
6
Slide the input power cable (routed on page 1-22) into one side of the double
cable pass through removed earlier.
7
Slide the 25-pin cable and load cell cable through the other side of the double
cable pass through cover.
8
Secure the cable pass through cover to the panel using the two screws removed
earlier.
Figure 2-2: Install the Load Cell
install the load cell
(the brake is not
shown for clarity)
load cell and 25-
pin cable on left,
input power cable
on right
route cables through
cable pass through
load cell cable
dyno