Adjusting the air flow – Dynojet Compressed Air Air/Fuel Ratio Module User Manual

Page 16

Advertising
background image

Compressed Air Air Fuel Ratio Module Installation and User Guide

C H A P T E R 1
Compressed Air Pump Assembly

1-12

A

DJUSTING

THE

A

IR

F

LOW

To ensure accurate readings, adjust the air flow as necessary to maintain 35L/min. If
you are unable to adjust the air flow to 35L/min., clean the pump then try to adjust
the air flow again. Refer to “Pump Maintenance—Stand Alone” on page 2-8 for more
information.
Adjust the air flow at the end of each exhaust probe to 35 L/min.
1

Attach six inches of the silicon tubing from the top port on the flow meter to the
copper sample tube.

2

Loosen the lock nut.

3

Turn the ball valve to the open position or turn on the air pump using the control
panel.

4

Rotate the vacuum generator exhaust port until the flow meter reads
35 L/min.

5

Tighten the lock nut.
Note: Make sure not to rotate the vacuum generator exhaust port when
tightening the lock nut.

6

Remove air flow meter and the six inches of silicon tube.
Note: Periodically check the air flow and adjust as necessary to maintain 35 L/min.

Figure 1-8: Adjusting the Air Flow—Stand Alone

lock nut

copper sample

tube

flow meter

sensor

vacuum generator

exhaust port

silicon tube