EFCO S5600 Inside Glazed User Manual
Page 24

EFCO CORPORATION 6/2012 PART NO. Y304
Page 24 of 29
Series 5600 Inside Glazed Installation Instructions
Section X: Glazing Installation
Re-glaze of Spandrel Glass From Interior
A.) The vision lite above the damaged or broken spandrel glass must be deglazed.
1. Remove the interior wedge.
2. Remove the glazing bead at the head.
3. Remove the glass.
4. Remove the horizontal at the top of the damaged or broken spandrel glass.
B.) Remove the damaged or broken glass and glazing material from the spandrel area.
C.) Remove any excess debris from the gutter that would clog-up the weep system or
cause staining of the glass and metal below.
D.) Follow the steps in “C” through “F” in “Glazing Installation” on page 23.
Note: It may be necessary to remove the ceiling line from the floor below to gain access
for gasket installation.
E.) Follow the steps in Section X to install the vision lites.
Vision Glass
Floor Line
Spandrel Glass