EFCO S5900 Inside Glazed User Manual
Page 17

EFCO CORPORATION 6/2012 PART NO. Y352
Page 17 of 18
Series 5900 Inside Glazed Curtain Wall Installation Instructions
E.)
After the infill is in the final position, apply the pressure plate and cover to the
top of the lite. Reseal all joints per page #9 “Frame Installation”. Apply the
dense wedge to the exterior side of the infill.
Section IX: Glazing
Glaze Spandrel Infill From Exterior
Glaze Spandrel Infill From Interior
A.)
The vision lite above the damaged or broken spandrel infill must be deglazed.
1.)
Remove the interior wedge gasket.
2.)
Remove the glazing bead at the head.
3.)
Remove the infill.
4.)
Remove the horizontal mullion at the top of the damaged or broken
spandrel infill.
B.)
Remove the gasket material from the spandrel area.
C.)
Remove any excess debris from the gutter that could clog the weep system or
cause staining of the infill and metal below.
Spandrel Infill
Floor line
Vision Infill
Dense preset gasket
Dense wedge
gasket
Dense wedge
gasket
Dense preset gasket
Before Reglaze
After Reglaze