Series 5900 Silicone Structural Glazed Curtain Wall Installation
IX: Preset Gaskets
Apply Preset Glazing Gaskets to Mullions
A.)
Apply sealant into gasket race a minimum of 2” each direction at each corner.
B.)
Remove glazing gaskets
from the reel and allow to
shrink.
C.)
Cut vertical gaskets D.L.O.
plus 1 ¾”.
D.)
Cut horizontal gaskets
D.L.O. plus ½”.
E.)
Seal all gasket corners: Pull
horizontal gaskets back, seal end,
and compress into the vertical
gasket to insure a snug fit.
F.)
Cut horizontal gaskets at
structural glazed mullions
D.L.O. plus ½”. Cut
vertical spacers to D.L.O.
plus 1 ¼”.
Preset gaskets
Preset gaskets
Note: If the gaskets are difficult to
insert into the gasket race, a
light coat of mineral spirits
can be applied to the gasket
for lubrication.
Preset spacer