Series 403x storefront installation instructions – EFCO 403X Series User Manual
Page 15

Series 403X Storefront Installation Instructions
EFCO 2013
Page 15
Section 3D. Expansion Mullions
Expansion mullions are required in elevations that are over 20’ - 25’ wide and can be used with both screw
spline and shear block systems.
Do Not use expansion mullions at entrance jambs. Locate the expansion mullion at the next vertical mullion over so
that the distance between expansion mullions is never more than 25’-0”.
Screw Spline System Fabrication Steps:
1. Follow steps 1-3 in Section 3A for cut lengths and hole preparations.
2. Follow standard unit construction method.
Shear Block System Fabrication Steps:
1. Follow steps 1, 2, and 5 in Section 3B for cut lengths and hole preparations.
2. Follow standard unit construction.
Fig. #13
W104
Note:
Expansion Joint gap must be
maintained before anchoring unit.
W104
21S8 21S7